Somalia Mogadishu-Turkey Training and Research Hospital is only powered by diesel generator currently.In this paper,the energy demand of this hospital is supplied by determining the optimum hybrid power renewable gene...Somalia Mogadishu-Turkey Training and Research Hospital is only powered by diesel generator currently.In this paper,the energy demand of this hospital is supplied by determining the optimum hybrid power renewable generating system.Therefore,numerous hybrid renewable power generating systems including the components like diesel generator,wind turbine,photovoltaic(PV)and battery are considered in different configurations.Eventually,they are technically,environmentally and economically analyzed by using the well-known HOMER software.Furthermore,a sensitivity analysis is also performed considering variations in three important parameters,namely average wind speed,current diesel price and also solar radiation.According to the results,the optimal system is the standalone Wind/Diesel/Battery hybrid renewable energy system(HRES)with the configuration of 1,000 kW wind turbine,350 kW diesel generator,250 kW power converters and 750 batteries.Additionally,this system has the net present cost of$5,056,700 as well as the cost of energy as$0.191/kWh.Lastly,it is clearly occurred that the Wind/Diesel/Battery HRES is eco-friendlier than other HRESs.展开更多
In this study, an off grid wind-solar hybrid power generation system was established at Afyon Kocatepe University to meet the energy need of lighting system of three different laboratories. It is planned to efficientl...In this study, an off grid wind-solar hybrid power generation system was established at Afyon Kocatepe University to meet the energy need of lighting system of three different laboratories. It is planned to efficiently use the energy obtained from the designed hybrid power generation system. For this purpose, PIC 16F877 was used in controlling of lighting load of laboratories. The off-grid wind-solar hybrid power generation system consists of 570 W 24 V mono crystal solar panels, 600 W wind power generation system and accumulator groups. The load control circuit made with PIC 16F877 is designed in a manner that will control the lighting armature groups individually activate and deactivate the armature groups according to intensity of illumination in environment. Besides, separately from generation and storing units constituting the hybrid power generation system, data in kWh are recorded by means of software in 10 seconds intervals. With the obtained power generation and storing data, analyzing of power consumption data when the load control system in active or passive position is made. According to analysis results, with controlling of lighting load and using of energy obtained from off grid wind-solar hybrid power generation system, 20.6% energy saving has been ensured.展开更多
文摘Somalia Mogadishu-Turkey Training and Research Hospital is only powered by diesel generator currently.In this paper,the energy demand of this hospital is supplied by determining the optimum hybrid power renewable generating system.Therefore,numerous hybrid renewable power generating systems including the components like diesel generator,wind turbine,photovoltaic(PV)and battery are considered in different configurations.Eventually,they are technically,environmentally and economically analyzed by using the well-known HOMER software.Furthermore,a sensitivity analysis is also performed considering variations in three important parameters,namely average wind speed,current diesel price and also solar radiation.According to the results,the optimal system is the standalone Wind/Diesel/Battery hybrid renewable energy system(HRES)with the configuration of 1,000 kW wind turbine,350 kW diesel generator,250 kW power converters and 750 batteries.Additionally,this system has the net present cost of$5,056,700 as well as the cost of energy as$0.191/kWh.Lastly,it is clearly occurred that the Wind/Diesel/Battery HRES is eco-friendlier than other HRESs.
基金supported by grant number 10-TEF-05 from Afyon Kocatepe University Scientific Research Projects Coordination Unit.
文摘In this study, an off grid wind-solar hybrid power generation system was established at Afyon Kocatepe University to meet the energy need of lighting system of three different laboratories. It is planned to efficiently use the energy obtained from the designed hybrid power generation system. For this purpose, PIC 16F877 was used in controlling of lighting load of laboratories. The off-grid wind-solar hybrid power generation system consists of 570 W 24 V mono crystal solar panels, 600 W wind power generation system and accumulator groups. The load control circuit made with PIC 16F877 is designed in a manner that will control the lighting armature groups individually activate and deactivate the armature groups according to intensity of illumination in environment. Besides, separately from generation and storing units constituting the hybrid power generation system, data in kWh are recorded by means of software in 10 seconds intervals. With the obtained power generation and storing data, analyzing of power consumption data when the load control system in active or passive position is made. According to analysis results, with controlling of lighting load and using of energy obtained from off grid wind-solar hybrid power generation system, 20.6% energy saving has been ensured.