Displacement damage effects on the charge-coupled device(CCD)induced by neutrons at the back-streaming white neutron source(Back-n)in the China Spallation Neutron Source(CSNS)are analyzed according to an online irradi...Displacement damage effects on the charge-coupled device(CCD)induced by neutrons at the back-streaming white neutron source(Back-n)in the China Spallation Neutron Source(CSNS)are analyzed according to an online irradiation experiment.The hot pixels,random telegraph signal(RTS),mean dark signal,dark current and dark signal non-uniformity(DSNU)induced by Back-n are presented.The dark current is calculated according to the mean dark signal at various integration times.The single-particle displacement damage and transient response are also observed based on the online measurement data.The trends of hot pixels,mean dark signal,DSNU and RTS degradation are related to the integration time and irradiation fluence.The mean dark signal,dark current and DSNU2 are nearly linear with neutron irradiation fluence when nearly all the pixels do not reach saturation.In addition,the mechanisms of the displacement damage effects on the CCD are demonstrated by combining the experimental results and technology computer-aided design(TCAD)simulation.Radiation-induced traps in the space charge region of the CCD will act as generation/recombination centers of electron-hole pairs,leading to an increase in the dark signal.展开更多
The objective of this work is to analyze the transient effects of ^60Co gamma rays in the CMOS image sensor (CIS) using the Monte Carlo method, based on Geant4. The track, energy spectrum, and angle of produced electr...The objective of this work is to analyze the transient effects of ^60Co gamma rays in the CMOS image sensor (CIS) using the Monte Carlo method, based on Geant4. The track, energy spectrum, and angle of produced electrons when gamma rays traversed a silicon or silicon dioxide cube were calculated. A simplified model of a 500 × 500 CIS array was established, and the transient effects of gamma rays in the CIS were simulated. The raw images were captured when the CIS was irradiated by gamma rays. The experimental results were compared with the simulation results. The characteristics of the typical events induced by transient effects were analyzed.展开更多
基金Project supported by the Foundation of State Key Laboratory of China(Grant Nos.SKLIPR1903Z,1803)the National Natural Science Foundation of China(Grant Nos.U2167208 and 11875223).
文摘Displacement damage effects on the charge-coupled device(CCD)induced by neutrons at the back-streaming white neutron source(Back-n)in the China Spallation Neutron Source(CSNS)are analyzed according to an online irradiation experiment.The hot pixels,random telegraph signal(RTS),mean dark signal,dark current and dark signal non-uniformity(DSNU)induced by Back-n are presented.The dark current is calculated according to the mean dark signal at various integration times.The single-particle displacement damage and transient response are also observed based on the online measurement data.The trends of hot pixels,mean dark signal,DSNU and RTS degradation are related to the integration time and irradiation fluence.The mean dark signal,dark current and DSNU2 are nearly linear with neutron irradiation fluence when nearly all the pixels do not reach saturation.In addition,the mechanisms of the displacement damage effects on the CCD are demonstrated by combining the experimental results and technology computer-aided design(TCAD)simulation.Radiation-induced traps in the space charge region of the CCD will act as generation/recombination centers of electron-hole pairs,leading to an increase in the dark signal.
基金supported by the National Natural Science Foundation of China(Nos.11805155,11875223,and 11690043)the Chinese Academy of Sciences strategic pilot science and technology project(No.XDA15015000)+1 种基金the Innovation Foundation of Radiation Application(No.KFZC2018040201)the Foundation of State Key Laboratory of China(Nos.SKLIPR1803 and 1610)
文摘The objective of this work is to analyze the transient effects of ^60Co gamma rays in the CMOS image sensor (CIS) using the Monte Carlo method, based on Geant4. The track, energy spectrum, and angle of produced electrons when gamma rays traversed a silicon or silicon dioxide cube were calculated. A simplified model of a 500 × 500 CIS array was established, and the transient effects of gamma rays in the CIS were simulated. The raw images were captured when the CIS was irradiated by gamma rays. The experimental results were compared with the simulation results. The characteristics of the typical events induced by transient effects were analyzed.