期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Electron density measurement by the three boundary channels of HCOOH laser interferometer on the HL-3 tokamak
1
作者 牟俊任 李永高 +5 位作者 李远 王再宏 丁宝钢 王浩西 易江 石中兵 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期88-93,共6页
Far-infrared(FIR)interferometer is widely used to measure the electron density in the magnetically confined fusion plasma devices.A new FIR laser interferometer with a total of 13 channels(8 horizontal channels and 5 ... Far-infrared(FIR)interferometer is widely used to measure the electron density in the magnetically confined fusion plasma devices.A new FIR laser interferometer with a total of 13 channels(8 horizontal channels and 5 oblique channels)is under development on the HL-3tokamak by using the formic-acid laser(HCOOH,f=694 GHz).In order to investigate the boundary electron density activity during the divertor discharge,three horizontal interferometry channels located at Z=-97,-76,76.5 cm have been successfully developed on HL-3 in 2023,and put into operation in recent experimental campaign,with a time resolution of<1.0μs and lineintegrated electron density resolution of~7.0×10^(16) m^(-2).This paper mainly focuses on the optical design of the three-channel interferometry system,as well as optical elements and recent experimental result on HL-3. 展开更多
关键词 electron density INTERFEROMETER HL-3
下载PDF
A precision control method for plasma electron density and Faraday rotation angle measurement on HL-2A
2
作者 Wei ZHANG Tongyu WU +3 位作者 baogang ding Yonggao LI Yan ZHOU Zejie YIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第7期130-135,共6页
The precision of plasma electron density and Faraday rotation angle measurement is a key indicator for far-infrared laser interferometer/polarimeter plasma diagnosis. To improve the precision, a new multi-channel high... The precision of plasma electron density and Faraday rotation angle measurement is a key indicator for far-infrared laser interferometer/polarimeter plasma diagnosis. To improve the precision, a new multi-channel high signal-to-noise ratio HCOOH interferometer/polarimeter has been developed on the HL-2A tokamak. It has a higher level requirement for phase demodulation precision. This paper introduces an improved real-time fast Fourier transform algorithm based on the field programmable gate array, which significantly improves the precision. We also apply a real-time error monitoring module (REMM) and a stable error inhibiting module (SEIM) for precision control to deal with the weak signal. We test the interferometer/polarimeter system with this improved precision control method in plasma discharge experiments and simulation experiments. The experimental results confirm that the plasma electron density precision is better than 1/3600 fringe and the Faraday rotation angle measurement precision is better than 1/900 fringe, while the temporal resolution is 80 ns. This performance can fully meet the requirements of HL-2A. 展开更多
关键词 precision control far-infrared laser phase difference HL-2A
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部