Preliminary design of a femtosecond timing system for large accelerator facilities 被引量:1
1
作者 Ming Liu Xiao-Lei Dai +1 位作者 Chong-Xian Yin bin-qing zhao 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第3期42-50,共9页
Large accelerator facilities require clocks and triggers with high accuracy to synchronize equipment and devices. A new femtosecond timing system was designed to meet the demands of new facilities. In this system, the... Large accelerator facilities require clocks and triggers with high accuracy to synchronize equipment and devices. A new femtosecond timing system was designed to meet the demands of new facilities. In this system, the radio-frequency signal is modulated in a continuous-wave laser carrier with frequency stabilization, and timing events are distributed in the same fiber. The phase drift is detected precisely, based on the principle of the Michelson interferometer. The phase drift is compensated with coarse and fine correctors afterward. We aim to realize the stable transmission of the RF signal and timing events for a long distance and duration, with the phase drift and additive jitter in femtoseconds. After the extension, the system will become a complete solution for the clock-and-trigger distribution of synchrotron radiation facilities, free-electron lasers, and other accelerators. The physics design, simulation analysis, and preliminary results are included in the paper. 展开更多
关键词 TIMING SYSTEM LARGE ACCELERATOR facilities SYNCHRONIZATION in femtoseconds
下载PDF
The front-end electronics design of dose monitors for beam delivery system of Shanghai Advanced Proton Therapy Facility
2
作者 bin-qing zhao Ming-Hua zhao +2 位作者 Ming Liu Chong-Xian Yin Hang Shu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第6期154-160,共7页
A front-end electronics of dose monitor has been developed for measuring irradiation dose to the patient in Shanghai Advanced Proton Therapy Facility.The parallel plate ionization chamber is used for the dose monitori... A front-end electronics of dose monitor has been developed for measuring irradiation dose to the patient in Shanghai Advanced Proton Therapy Facility.The parallel plate ionization chamber is used for the dose monitoring.Unlike the traditional method of recycling capacitor integration and voltage-to-frequency conversion,this dose monitor electronics uses the trans-impedance amplifier and analog-to-digital conversion method.It performs satisfactorily,with the integral nonlinearity of less than ±0.04 nA in the range of-400 to 50 nA and the resolution of about±0.6 nA. 展开更多
关键词 FRONT-END electronics DOSE MONITOR PROTON therapy
下载PDF