Finding the electromagnetic(EM) counterpart of binary compact star merger, especially the binary neutron star(BNS) merger,is critically important for gravitational wave(GW) astronomy, cosmology and fundamental physics...Finding the electromagnetic(EM) counterpart of binary compact star merger, especially the binary neutron star(BNS) merger,is critically important for gravitational wave(GW) astronomy, cosmology and fundamental physics. On Aug. 17, 2017,Advanced LIGO and Fermi/GBM independently triggered the first BNS merger, GW170817, and its high energy EM counterpart,GRB 170817 A, respectively, resulting in a global observation campaign covering gamma-ray, X-ray, UV, optical, IR, radio as well as neutrinos. The High Energy X-ray telescope(HE) onboard Insight-HXMT(Hard X-ray Modulation Telescope) is the unique high-energy gamma-ray telescope that monitored the entire GW localization area and especially the optical counterpart(SSS17 a/AT2017 gfo) with very large collection area(~1000 cm^2) and microsecond time resolution in 0.2-5 MeV. In addition,Insight-HXMT quickly implemented a Target of Opportunity(ToO) observation to scan the GW localization area for potential X-ray emission from the GW source. Although Insight-HXMT did not detect any significant high energy(0.2-5 MeV) radiation from GW170817, its observation helped to confirm the unexpected weak and soft nature of GRB 170817 A. Meanwhile,Insight-HXMT/HE provides one of the most stringent constraints(~10^(-7) to 10^(-6) erg/cm^2/s) for both GRB170817 A and any other possible precursor or extended emissions in 0.2-5 MeV, which help us to better understand the properties of EM radiation from this BNS merger. Therefore the observation of Insight-HXMT constitutes an important chapter in the full context of multi-wavelength and multi-messenger observation of this historical GW event.展开更多
As China’s first X-ray astronomical satellite, the Hard X-ray Modulation Telescope (HXMT), which was dubbed as Insight-HXMT after the launch on June 15, 2017, is a wide-band(1-250 ke V) slat-collimator-based X-ray as...As China’s first X-ray astronomical satellite, the Hard X-ray Modulation Telescope (HXMT), which was dubbed as Insight-HXMT after the launch on June 15, 2017, is a wide-band(1-250 ke V) slat-collimator-based X-ray astronomy satellite with the capability of all-sky monitoring in 0.2-3 Me V. It was designed to perform pointing, scanning and gamma-ray burst(GRB)observations and, based on the Direct Demodulation Method (DDM), the image of the scanned sky region can be reconstructed.Here we give an overview of the mission and its progresses, including payload, core sciences, ground calibration/facility, ground segment, data archive, software, in-orbit performance, calibration, background model, observations and some preliminary results.展开更多
The Insight-Hard X-ray Modulation Telescope(Insight-HXMT) is a broadband X-ray and γ-ray(1-3000 ke V) astronomy satellite. One of its three main telescopes is the High Energy X-ray telescope(HE). The main detector pl...The Insight-Hard X-ray Modulation Telescope(Insight-HXMT) is a broadband X-ray and γ-ray(1-3000 ke V) astronomy satellite. One of its three main telescopes is the High Energy X-ray telescope(HE). The main detector plane of HE comprises 18 Na I(Tl)/Cs I(Na) phoswich detectors, where Na I(Tl) is used as the primary detector to measure ~ 20-250 ke V photons incident from the field of view(FOV) defined by collimators, and Cs I(Na) is used as the active shielding detector to Na I(Tl) by pulse shape discrimination. Additionally, Cs I(Na) is used as an omnidirectional γ-ray monitor. The HE collimators have a diverse FOV,i.e. 1.1°×5.7°(15 units), 5.7°×5.7°(2 units), and blocked(1 unit). Therefore, the combined FOV of HE is approximately5.7°×5.7°. Each HE detector has a diameter of 190 mm resulting in a total geometrical area of approximately 5100 cm2, and the energy resolution is ~15% at 60 ke V. For each recorded X-ray event by HE, the timing accuracy is less than 10 μs and the deadtime is less than 10 μs. HE is used for observing spectra and temporal variability of X-ray sources in the 20-250 ke V band either by pointing observations for known sources or scanning observations to unveil new sources. Additionally, HE is used for monitoring the γ-ray burst in 0.2-3 Me V band. This paper not only presents the design and performance of HE instruments but also reports results of the on-ground calibration experiments.展开更多
The high energy cosmic-radiation detection(HERD)facility is a space mission designed for detecting cosmic ray(CR)electrons,γ-rays up to tens of TeV and CR nuclei from proton to iron up to several PeV.The main instrum...The high energy cosmic-radiation detection(HERD)facility is a space mission designed for detecting cosmic ray(CR)electrons,γ-rays up to tens of TeV and CR nuclei from proton to iron up to several PeV.The main instrument of HERD is a 3-D imaging calorimeter(CALO)composed of nearly ten thousand lutetium yttrium orthosilicate(LYSO,with cerium doping)crystal cubes.A large dynamic range of single HERD CALO Cell(HCC)is necessary to achieve HERD’s PeV observation objectives,which means that the response of HCC should maintain a good linearity from minimum ionizing particle(MIP)calibration to PeV shower maximum.In order to study the linearity ofHCC over such a large energy range,a beam test has been implemented at the E2 and E3 beam lines of BEPC.High intensity pulsed electron beam provided by E2 line is used for producing high energy density within HCC;π^(+)/proton provided by E3 line are used forHCCcalibration.The results showthat no saturation effect occurs and the linearity ofHCCis better than 10%from 30 MeV(1MIP)to 1.1×10^(3) TeV(energy density is 93 TeV/cm^(3)),which can meet the requirement mentioned above.展开更多
基金supported by the National Program on Key Research and Development Project(Grant No.2016YFA0400800)from the Ministry of Science and Technology of China(MOST)the Strategic Priority Research Program of the Chinese Academy of Sciences(Grant No.XDB23040400)the Hundred Talent Program of Chinese Academy of Sciences,the National Natural Science Foundation of China(Grant Nos.11233001,11503027,11403026,11473027,and11733009)
文摘Finding the electromagnetic(EM) counterpart of binary compact star merger, especially the binary neutron star(BNS) merger,is critically important for gravitational wave(GW) astronomy, cosmology and fundamental physics. On Aug. 17, 2017,Advanced LIGO and Fermi/GBM independently triggered the first BNS merger, GW170817, and its high energy EM counterpart,GRB 170817 A, respectively, resulting in a global observation campaign covering gamma-ray, X-ray, UV, optical, IR, radio as well as neutrinos. The High Energy X-ray telescope(HE) onboard Insight-HXMT(Hard X-ray Modulation Telescope) is the unique high-energy gamma-ray telescope that monitored the entire GW localization area and especially the optical counterpart(SSS17 a/AT2017 gfo) with very large collection area(~1000 cm^2) and microsecond time resolution in 0.2-5 MeV. In addition,Insight-HXMT quickly implemented a Target of Opportunity(ToO) observation to scan the GW localization area for potential X-ray emission from the GW source. Although Insight-HXMT did not detect any significant high energy(0.2-5 MeV) radiation from GW170817, its observation helped to confirm the unexpected weak and soft nature of GRB 170817 A. Meanwhile,Insight-HXMT/HE provides one of the most stringent constraints(~10^(-7) to 10^(-6) erg/cm^2/s) for both GRB170817 A and any other possible precursor or extended emissions in 0.2-5 MeV, which help us to better understand the properties of EM radiation from this BNS merger. Therefore the observation of Insight-HXMT constitutes an important chapter in the full context of multi-wavelength and multi-messenger observation of this historical GW event.
基金project funded by China National Space Administration(CNSA)and the Chinese Academy of Sciences(CAS)support from the National Key Research and Development Program of China(Grant No.2016YFA0400800)+1 种基金the Strategic Priority Research Program of the Chinese Academy of Sciences(Grant Nos.XDA04010202,XDA04010300,and XDB23040400)the National Natural Science Foundation of China(Grant Nos.U1838201,and U1838102).
文摘As China’s first X-ray astronomical satellite, the Hard X-ray Modulation Telescope (HXMT), which was dubbed as Insight-HXMT after the launch on June 15, 2017, is a wide-band(1-250 ke V) slat-collimator-based X-ray astronomy satellite with the capability of all-sky monitoring in 0.2-3 Me V. It was designed to perform pointing, scanning and gamma-ray burst(GRB)observations and, based on the Direct Demodulation Method (DDM), the image of the scanned sky region can be reconstructed.Here we give an overview of the mission and its progresses, including payload, core sciences, ground calibration/facility, ground segment, data archive, software, in-orbit performance, calibration, background model, observations and some preliminary results.
基金China National Space Administration(CNSA)and the Chinese Academy of Sciences(CAS)the National Key Research and Development Program of China(Grant No.2016YFA0400800)the Strategic Priority Research Program of the Chinese Academy of Sciences(Grant Nos.XDA04010202,XDA04010300,and XDB23040400).
文摘The Insight-Hard X-ray Modulation Telescope(Insight-HXMT) is a broadband X-ray and γ-ray(1-3000 ke V) astronomy satellite. One of its three main telescopes is the High Energy X-ray telescope(HE). The main detector plane of HE comprises 18 Na I(Tl)/Cs I(Na) phoswich detectors, where Na I(Tl) is used as the primary detector to measure ~ 20-250 ke V photons incident from the field of view(FOV) defined by collimators, and Cs I(Na) is used as the active shielding detector to Na I(Tl) by pulse shape discrimination. Additionally, Cs I(Na) is used as an omnidirectional γ-ray monitor. The HE collimators have a diverse FOV,i.e. 1.1°×5.7°(15 units), 5.7°×5.7°(2 units), and blocked(1 unit). Therefore, the combined FOV of HE is approximately5.7°×5.7°. Each HE detector has a diameter of 190 mm resulting in a total geometrical area of approximately 5100 cm2, and the energy resolution is ~15% at 60 ke V. For each recorded X-ray event by HE, the timing accuracy is less than 10 μs and the deadtime is less than 10 μs. HE is used for observing spectra and temporal variability of X-ray sources in the 20-250 ke V band either by pointing observations for known sources or scanning observations to unveil new sources. Additionally, HE is used for monitoring the γ-ray burst in 0.2-3 Me V band. This paper not only presents the design and performance of HE instruments but also reports results of the on-ground calibration experiments.
基金This research was supported by National Natural Science Foundation of China,Grant No.11327303,11473028 and 11675196International Science and Technology Cooperation Program of China,Grant No.2015DFA10140+3 种基金Interdisciplinary Innovation Team Project of Chinese Academy of Sciences(Research Team of The High Energy cosmic-Radiation Detection)Qianren start-up,Grant No.292012312D1117210Strategic Pioneer Program in Space Science,Chinese Academy of Sciences,Grant No.XDA04075600Youth Innovation Promotion Association of CAS,Grant No.2014009.The authors would like to thank Dr.Sun Jianchao,Dr.Zhang Xuan,Dr.Zhang Xiaofeng and Dr.Ning Zhe for their support.
文摘The high energy cosmic-radiation detection(HERD)facility is a space mission designed for detecting cosmic ray(CR)electrons,γ-rays up to tens of TeV and CR nuclei from proton to iron up to several PeV.The main instrument of HERD is a 3-D imaging calorimeter(CALO)composed of nearly ten thousand lutetium yttrium orthosilicate(LYSO,with cerium doping)crystal cubes.A large dynamic range of single HERD CALO Cell(HCC)is necessary to achieve HERD’s PeV observation objectives,which means that the response of HCC should maintain a good linearity from minimum ionizing particle(MIP)calibration to PeV shower maximum.In order to study the linearity ofHCC over such a large energy range,a beam test has been implemented at the E2 and E3 beam lines of BEPC.High intensity pulsed electron beam provided by E2 line is used for producing high energy density within HCC;π^(+)/proton provided by E3 line are used forHCCcalibration.The results showthat no saturation effect occurs and the linearity ofHCCis better than 10%from 30 MeV(1MIP)to 1.1×10^(3) TeV(energy density is 93 TeV/cm^(3)),which can meet the requirement mentioned above.