The main goal of this work was to develop an optimal self-microemulsifying paclitaxel prepared with PLGA and solubilizer such as tetraglycol, Cremophor ELP, and Labrasol. The prepared PTx-loaded SMES showed the size o...The main goal of this work was to develop an optimal self-microemulsifying paclitaxel prepared with PLGA and solubilizer such as tetraglycol, Cremophor ELP, and Labrasol. The prepared PTx-loaded SMES showed the size of the range of 80–130 nm by dy-namic light scattering and a spherical shape by atomic force microscopy. In experiment of storage stability in deionized water (DW) or blood condition, PTx-loaded SMES showed good stability in DW and comparable stability in blood condition at 37oC for 7 days. In addition, PTx-loaded SMES showed a sig-nificant inhibitory effect on B16F10 melanoma proli-feration. In conclusion, we confirmed that the for-mulations tried in this study could be used as admin-istration form for animal trials of PTx.展开更多
The bare metal stent (BMS) used in the blood vessel caused the restenosis after the operation due to formation and proliferation of neointimal. Recently, as a method to overcome the problems of BMS, drug eluting stent...The bare metal stent (BMS) used in the blood vessel caused the restenosis after the operation due to formation and proliferation of neointimal. Recently, as a method to overcome the problems of BMS, drug eluting stent (DES) is developed and being applied to human body which has drug reducing restenosis applied on the metal surface. DES has the advantage of greatly reducing the restenosis after the operation;however, metal stent remains in the body after the drug is released causing issues such as late thrombosis and restenosis so that currently the attention is increasing for biodegradable materials that reduce restenosis and thrombosis by degrading as a certain amount of time passes after the drug is released by the stent material. In this review, the study trend of biodegradable stent will be explained.展开更多
文摘The main goal of this work was to develop an optimal self-microemulsifying paclitaxel prepared with PLGA and solubilizer such as tetraglycol, Cremophor ELP, and Labrasol. The prepared PTx-loaded SMES showed the size of the range of 80–130 nm by dy-namic light scattering and a spherical shape by atomic force microscopy. In experiment of storage stability in deionized water (DW) or blood condition, PTx-loaded SMES showed good stability in DW and comparable stability in blood condition at 37oC for 7 days. In addition, PTx-loaded SMES showed a sig-nificant inhibitory effect on B16F10 melanoma proli-feration. In conclusion, we confirmed that the for-mulations tried in this study could be used as admin-istration form for animal trials of PTx.
文摘The bare metal stent (BMS) used in the blood vessel caused the restenosis after the operation due to formation and proliferation of neointimal. Recently, as a method to overcome the problems of BMS, drug eluting stent (DES) is developed and being applied to human body which has drug reducing restenosis applied on the metal surface. DES has the advantage of greatly reducing the restenosis after the operation;however, metal stent remains in the body after the drug is released causing issues such as late thrombosis and restenosis so that currently the attention is increasing for biodegradable materials that reduce restenosis and thrombosis by degrading as a certain amount of time passes after the drug is released by the stent material. In this review, the study trend of biodegradable stent will be explained.