期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Cooling Water Flow Rate Calculation for Hearth of Large Blast Furnaces
1
作者 LI Hengxu che yiunan +2 位作者 ZHOU Zhe WANG Qi WANG Hongtao 《China's Refractories》 CAS 2015年第2期16-20,共5页
The cooling water flow rate for hearth of large blast furnaces was calculated by simulation. The results show that the cooling water flow rate shall be above 4 200m3/ h for hearth of large blast furnaces; to meet requ... The cooling water flow rate for hearth of large blast furnaces was calculated by simulation. The results show that the cooling water flow rate shall be above 4 200m3/ h for hearth of large blast furnaces; to meet requirements of the increasing smelting intensity and to ensure the safety at the end of the first campaign,the designed maximum cooling water flow rate should be 5 900m3/ h; according to the flow distribution stability and the calculated resistance loss,hearth cooling stave pipes with the specification of 76 mm × 6 mm shall be adopted to assure the flow velocity in pipes of hearth cooling stave in the range of 1. 9- 2. 3 m / s. 展开更多
关键词 hearth of blast furnaces cooling water flow rate simulation calculation
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部