期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Measurement of the ^(27)Al(n,2n)^(26)Al Cross Section Using Accelerator Mass Spectrometry 被引量:2
1
作者 ZHAO Qiang LU Xiang-yang +7 位作者 GUO Zhi-yu SHI Zhao-min WANG Jian-jun LIU Ke-xin LI Bin LI Kun chen jia-er LU Han-lin 《Chinese Physics Letters》 SCIE CAS CSCD 1998年第1期8-9,共2页
The ^(27)Al(n,2n)^(26)Al cross section is of great interest for the waste disposal assessment of fusion reactor materials and fusion research.By the technique of accelerator mass spectrometry,we have measured the ^(26... The ^(27)Al(n,2n)^(26)Al cross section is of great interest for the waste disposal assessment of fusion reactor materials and fusion research.By the technique of accelerator mass spectrometry,we have measured the ^(26)Al/^(27)Al ratio of Al2O3 powder samples which were irradiated by a neutron beam.The neutron reaction cross section for ^(27)Al(n,2n)^(26)Al in the energy range of 14.8-14.9MeV are deduced. 展开更多
关键词 IRRADIATED
下载PDF
Radio-Frequency Power Test of a Four-Rod RFQ Accelerator for PKUNIFTY
2
作者 ZENG Hong-Jin LIU Ge +9 位作者 LU Yuan-Rong chen Wei ZHOU Quan-Feng ZHU Kun XIA Wen-Long SHI Ben-Liang GAO Shu-Li YAN Xue-Qing GUO Zhi-Yu chen jia-er 《Chinese Physics Letters》 SCIE CAS CSCD 2012年第6期106-109,共4页
A four-rod radio frequency quadruple (RFQ) accelerator is designed,manufactured,installed and commissioned for the Peking University Neutron Imaging Facility (PKUNIFTY).This 2699.6-mm-long RFQ accelerator with the mea... A four-rod radio frequency quadruple (RFQ) accelerator is designed,manufactured,installed and commissioned for the Peking University Neutron Imaging Facility (PKUNIFTY).This 2699.6-mm-long RFQ accelerator with the mean aperture radius of 3.88mm is operating at 201.5MHz in pulse mode.An inter-electrode voltage of 70kV is needed to accelerate the injected 50keV 40mA D+ ions up to 2MeV.We present the rf system,high rf power feeder design,lowver rf measurements and higher rf power test.Especially,the rf commissioning was carried out with rf power up to ~280 k W and duty factor of 4%.The measured x-ray spectrum shows that the rf inter-electrode voltage reaches 70.7 kV.It is found that the specific shunt impedance of the RFQ cavity reaches 52.7kΩ.m. 展开更多
关键词 RFQ RADIUS CAVITY
下载PDF
Power Test of the Ladder IH-RFQ Accelerator at Peking University
3
作者 LU Yuan-Rong chen Wei +5 位作者 NIE Yuan-Cun LIU Ge GAO Shu-Li ZENG Hong-Jin YAN Xue-Qing chen jia-er 《Chinese Physics Letters》 SCIE CAS CSCD 2011年第7期89-92,共4页
A 104-MHz ladder interdigital-H radio frequency quadrupole accelerator(T-IH-RFQ)is developed for applying RFQs to heavy ion implantation and accelerator-based mass spectroscopy in recent years at the Institute of Heav... A 104-MHz ladder interdigital-H radio frequency quadrupole accelerator(T-IH-RFQ)is developed for applying RFQs to heavy ion implantation and accelerator-based mass spectroscopy in recent years at the Institute of Heavy Ion Physics,Peking University.It could accelerate ions with a mass-to-charge ratio of less than 14,from 2.9 keV/u to 35.7 keV/u within a length of 1.1 m.The T-IH-RFQ cavity operating at H21(0)mode was constructed successfully.Based on a well designed rf power feeding system,the cavity was cold measured and tested with high rf power.In the case of cold measurement,the rf properties were obtained using a vector network analyzer with the help of a perturbation capacitor.During a high power test,the inter−electrode voltage was derived from the energy spectrum of x-rays measured by a high purity Ge detector.The results show that the specific shunt impedance of the T-IH-RFQ cavity reaches 178 kΩm,which could meet the requirements of beam dynamics design. 展开更多
关键词 PURITY IMPLANTATION APPLYING
下载PDF
上一页 1 下一页 到第