Monitoring high-temperature vibrations is critical in aerospace engineering,industrial manufacturing,and energy production,where harsh conditions necessitate robust vibration sensors for detecting anomalous signals.Ho...Monitoring high-temperature vibrations is critical in aerospace engineering,industrial manufacturing,and energy production,where harsh conditions necessitate robust vibration sensors for detecting anomalous signals.However,the accuracy of such sensors is often compromised by crosstalk between temperature and vibration signals.This study introduces a high-temperature vibration sensor based on langasite(LGS)surface acoustic wave(SAW)technology,designed to withstand temperatures up to 500℃.The sensor demonstrates high sensitivity,ranging from 12.54 kHz/g at 25℃ to 15.63 k Hz/g at 500℃.A comprehensive mechanical and electrical coupling model for the SAW vibration sensor was developed by integrating theoretical equations with numerical simulations to optimize the sensor's performance.Additionally,a novel decoupling algorithm for temperature and vibration was established,achieving thermomechanical decoupling with precise vibration parameters.Experimental results indicated a maximum relative deviation of 4.67%for the algorithm.In conclusion,the proposed LGS SAW vibration sensor emerges as a promising solution for the accurate detection of multiple parameters in high-temperature vibration monitoring.展开更多
OBJECTIVE:To observe and explore the effect of Fuling(Poria) in alleviating the spleen deficiency symptom pattern(SDSP).METHODS:We established an animal model of SDS in Sprague-Dawley(SD) rats by treating them with de...OBJECTIVE:To observe and explore the effect of Fuling(Poria) in alleviating the spleen deficiency symptom pattern(SDSP).METHODS:We established an animal model of SDS in Sprague-Dawley(SD) rats by treating them with deficiency-inducing factors,including irregular feeding and tail clamping.Mice were administered Fuling(Poria) and its extracts(raw/cooked powder,aqueous/alcohol extract) by gavage once a day for 21 d.The body weight,rectal temperature,and spleen and thymus organ coefficients were calculated.The levels of motilin(MTL),gastrin(GAS),aquaporin 2(AQP2),interleukin 2(IL-2),IL-4,and 5-hydroxytryptamine(5-HT) in the serum and the level of AQP2 in the kidneys were evaluated by enzyme-linked immunosorbent assay.RESULTS:Fuling(Poria) and its extracts did not change the body weight,rectal temperature,and organ coefficients of the spleen and thymus.However,it reduced the levels of MTL and GAS and increased the levels of IL-2 and AQP2.In addition,the levels of IL-4 and 5-HT showed no significant alteration.CONCLUSIONS:These results suggested the crucial function of Fuling(Poria) in SDSP,especially promoting digestive function and water metabolism.展开更多
基金supported by the National Natural Science Foundation of China(Grant Nos.U1837209 and 52105594)the Fundamental Research Program of Shanxi Province(Grant No.20210302124274)+4 种基金the Scientific and Technological Innovation Programs of Higher Education Institutions in Shanxi(Grant No.2023L361)the Outstanding Young Talents Support Plan of Shanxi Provincethe Young Sanjin Scholar Distinguished Professor Plan of Shanxi Provincethe Innovative Research Group Project of the National Natural Science Foundation of China(Grant No.51821003)the Shanxi‘1331 Project’Key Subjects Construction。
文摘Monitoring high-temperature vibrations is critical in aerospace engineering,industrial manufacturing,and energy production,where harsh conditions necessitate robust vibration sensors for detecting anomalous signals.However,the accuracy of such sensors is often compromised by crosstalk between temperature and vibration signals.This study introduces a high-temperature vibration sensor based on langasite(LGS)surface acoustic wave(SAW)technology,designed to withstand temperatures up to 500℃.The sensor demonstrates high sensitivity,ranging from 12.54 kHz/g at 25℃ to 15.63 k Hz/g at 500℃.A comprehensive mechanical and electrical coupling model for the SAW vibration sensor was developed by integrating theoretical equations with numerical simulations to optimize the sensor's performance.Additionally,a novel decoupling algorithm for temperature and vibration was established,achieving thermomechanical decoupling with precise vibration parameters.Experimental results indicated a maximum relative deviation of 4.67%for the algorithm.In conclusion,the proposed LGS SAW vibration sensor emerges as a promising solution for the accurate detection of multiple parameters in high-temperature vibration monitoring.
基金Supported by National Key Research and Development Program of China:Study on the Core Efficacy Evaluation of Fuling(Poria)(No.2017YFC1703005)。
文摘OBJECTIVE:To observe and explore the effect of Fuling(Poria) in alleviating the spleen deficiency symptom pattern(SDSP).METHODS:We established an animal model of SDS in Sprague-Dawley(SD) rats by treating them with deficiency-inducing factors,including irregular feeding and tail clamping.Mice were administered Fuling(Poria) and its extracts(raw/cooked powder,aqueous/alcohol extract) by gavage once a day for 21 d.The body weight,rectal temperature,and spleen and thymus organ coefficients were calculated.The levels of motilin(MTL),gastrin(GAS),aquaporin 2(AQP2),interleukin 2(IL-2),IL-4,and 5-hydroxytryptamine(5-HT) in the serum and the level of AQP2 in the kidneys were evaluated by enzyme-linked immunosorbent assay.RESULTS:Fuling(Poria) and its extracts did not change the body weight,rectal temperature,and organ coefficients of the spleen and thymus.However,it reduced the levels of MTL and GAS and increased the levels of IL-2 and AQP2.In addition,the levels of IL-4 and 5-HT showed no significant alteration.CONCLUSIONS:These results suggested the crucial function of Fuling(Poria) in SDSP,especially promoting digestive function and water metabolism.