DC FLOW SUPPRESSION IN A SINGLE-STAGE G-M TYPE PULSE TUBE COOLER
1
作者 JIANGYan-long chenguo-bang THUMMESGuenter 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2004年第4期277-280,共4页
An experimental investigation on DC flow suppression in a single-stage G-M type pulse tube cooler is made. The influence of DC flow induced by the introduction of the double-inlet on the refrigeration performance of t... An experimental investigation on DC flow suppression in a single-stage G-M type pulse tube cooler is made. The influence of DC flow induced by the introduction of the double-inlet on the refrigeration performance of the cooler is experimentally examined. Two parallelplaced needle valves with an opposite flow direction called as double-valved configuration, instead of conventional single-valved configuration as the double-inlet is used to reduce the DC flow. With the double-valved configuration, the minimum temperatures of 18.4 K and 14.7 K, and the cooling powers of 11.5 W and 29.5 W are also obtained by RW2 and CP4000, respectively. 展开更多
关键词 DC流 抑制方法 脉冲冷却管 优化设计