For qualifying the anti-shock performance of shipboard equipments and simulating actual underwater explosion environments, a novel dual-wave shock test machine is proposed to increase testing capability of shock test ...For qualifying the anti-shock performance of shipboard equipments and simulating actual underwater explosion environments, a novel dual-wave shock test machine is proposed to increase testing capability of shock test machines as well as to meet certain shock testing specification. The machine can generate a double-pulse acceleration shock for test articles according to specification defined in BV043/85. On the basis of the impact theory, a nonlinear dynamic model of the hydraulically-actuated test machine is established with thorough analysis on its mechanism which involves conversion of gas potential energy and dissipation of kinetic energy. Simulation results have demonstrated that the machine can produce a double-pulse acceleration shock in the time domain or a desired shock response spectrum in the frequency domain, which sets a theoretical base for the construction of the proposed machine.展开更多
A specially designed fluid damper used as negative shock pulse generator in the shock resistance test system to dissipate the shock input energy in transient time duration is presented. The theoretical modeling based ...A specially designed fluid damper used as negative shock pulse generator in the shock resistance test system to dissipate the shock input energy in transient time duration is presented. The theoretical modeling based on the three-dimensional equation of heat transfer through a fluid element is created to predict the viscous heating in the fluid damper under shock conditions. A comprehensive experimental program that investigates the problem of viscous heating in the fluid damper under different shock conditions is conducted on the shock test machine to validate the analytical expression. Temperature histories for the fluid within the damper at two locations, the annular-oriflce and the-end-of stroke of the damper, are recorded. The experimental results show that the theoretical model can offer a very dependable prediction for the temperature histories in the damper for increasing input velocity. The theoretical model and experimental data both clearly indicate that the viscous heating in the damper is directly related to the maximum shock velocity input and the pressure between the two sides of the piston head.展开更多
基金supported by China Naval Armament Department (No. 05131/1046).
文摘For qualifying the anti-shock performance of shipboard equipments and simulating actual underwater explosion environments, a novel dual-wave shock test machine is proposed to increase testing capability of shock test machines as well as to meet certain shock testing specification. The machine can generate a double-pulse acceleration shock for test articles according to specification defined in BV043/85. On the basis of the impact theory, a nonlinear dynamic model of the hydraulically-actuated test machine is established with thorough analysis on its mechanism which involves conversion of gas potential energy and dissipation of kinetic energy. Simulation results have demonstrated that the machine can produce a double-pulse acceleration shock in the time domain or a desired shock response spectrum in the frequency domain, which sets a theoretical base for the construction of the proposed machine.
基金Chinese Navy Warship Research Center(No.05131-1046)
文摘A specially designed fluid damper used as negative shock pulse generator in the shock resistance test system to dissipate the shock input energy in transient time duration is presented. The theoretical modeling based on the three-dimensional equation of heat transfer through a fluid element is created to predict the viscous heating in the fluid damper under shock conditions. A comprehensive experimental program that investigates the problem of viscous heating in the fluid damper under different shock conditions is conducted on the shock test machine to validate the analytical expression. Temperature histories for the fluid within the damper at two locations, the annular-oriflce and the-end-of stroke of the damper, are recorded. The experimental results show that the theoretical model can offer a very dependable prediction for the temperature histories in the damper for increasing input velocity. The theoretical model and experimental data both clearly indicate that the viscous heating in the damper is directly related to the maximum shock velocity input and the pressure between the two sides of the piston head.