In order to analyze the influence of the hole chamfer on the metering performances of a Multi-hole Orifice Flowmeter and optimize the related orifice structure,a multi-hole orifice flowmeter with DN80 and throttle rat...In order to analyze the influence of the hole chamfer on the metering performances of a Multi-hole Orifice Flowmeter and optimize the related orifice structure,a multi-hole orifice flowmeter with DN80 and throttle ratio of 0.45 was considered in the present study.The flow field characteristics were determined in the framework of a CFD technique.The results show that the multi-hole orifice flowmeter with filleting transition around the throttle orifice has higher accuracy in a wide range of the space of parameters,and is more suitable for accurate measurement of fluid in process control.展开更多
基金supports of Hebei province high-tech industry multiplier project(No.16211702D)Chengde science and technology&development project(No.20152013).
文摘In order to analyze the influence of the hole chamfer on the metering performances of a Multi-hole Orifice Flowmeter and optimize the related orifice structure,a multi-hole orifice flowmeter with DN80 and throttle ratio of 0.45 was considered in the present study.The flow field characteristics were determined in the framework of a CFD technique.The results show that the multi-hole orifice flowmeter with filleting transition around the throttle orifice has higher accuracy in a wide range of the space of parameters,and is more suitable for accurate measurement of fluid in process control.