期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
内镜下氩离子修复胆道和胃肠道金属支架
1
作者 Vanbiervliet G. Piche T. +1 位作者 caroli-bosc f.x. 徐小洁 《世界核心医学期刊文摘(胃肠病学分册)》 2005年第9期17-18,共2页
Background and study aims: The aim of this study was to assess the feasibility and efficiency of plasma argon trimming of gastrointestinal and biliary metallic stents. Patients and methods: A total of 31 patients unde... Background and study aims: The aim of this study was to assess the feasibility and efficiency of plasma argon trimming of gastrointestinal and biliary metallic stents. Patients and methods: A total of 31 patients underwent plasma argon trimming of their metallic stents (14 women, 17 men; mean ±SD age 73 ±12.2 years, range 46-96 years). Of these 31 patients, 24 had had covered or noncovered Unistep Wallstents placed in the biliary tract (13 patients with pancreatic neoplasms, five patients with Vater ampulloma, five patients with biliary tract carcinoma and one patient with chronic calcifiying pancreatitis); three patients had noncovered Enteral Unistep Wallstents (pyloroduoden- al); two patients with obstructive colorectal carcinoma had a noncovered Bard Memotherm stent inserted; and two patients had noncovered Ultraflex stents placed for esophageal carcinoma. Endoscopic trimming of the stents was performed under propofol-induced general anesthesia, with the power set at 70-80 watts and an argon flow of 0.8 liters/minute. Results: Complete and satisfactory trimming of the stents was possible, without complications (mean follow-up 15.8 months), in all patients except one, a patient with a covered biliary Wallstent. In 13 patients with biliary or Enteral Wallstents the trimming procedure was preventive. In eight patients with ulceration and/or hemorrhage (duodenal or rectal), healing was achieved after stent trimming and epinephrine (adrenaline) injection followed by electrocoagulation. Stent trimming restored patency of the duodenal lumen in six patients and of the esophageal lumen in two patients, and was done to allow insertion of a biliary stent in one patient whose duodenal stent was covering the papilla. In one patient with rectal tenesmus, stent shortening resulted in complete resolution of symptoms. Conclusions: Endsocopic plasma argon trimming of metallic stents is an efficient procedure which allows easy, reproducible and well-tolerated correction of complications that arise due to these prostheses. 展开更多
关键词 金属支架 氩离子 支架放置 结肠直肠癌 壶腹周围癌 胆管癌 胰腺肿瘤 VATER 患者耐受性 巴德
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部