期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Mid-infrared flat-topped broadband chiral helix metamaterials based on indium tin oxide and their chiral properties 被引量:1
1
作者 Wentao Zhang Weijie Shi +1 位作者 Hui Guo changchun yan 《Chinese Optics Letters》 SCIE EI CAS CSCD 2021年第11期72-76,共5页
We proposed a periodic mid-infrared broadband chiral structure. Its unit cell consists of four indium tin oxide(ITO) helix subunits with different radii. The simulation results show that the flat-topped broadband circ... We proposed a periodic mid-infrared broadband chiral structure. Its unit cell consists of four indium tin oxide(ITO) helix subunits with different radii. The simulation results show that the flat-topped broadband circular dichroism(CD) can be achieved in the mid-infrared band by optimizing the parameters of helix structures. The simulation results also show that compared with the metallic(Ag and Au) helix structures, the ITO helix structure proposed exhibits evidently better broadband CD and optical activity, which provides a new idea for the design of broadband polarization state control devices in the mid-infrared band. 展开更多
关键词 MID-INFRARED flat-topped broadband chiral helix metamaterial
原文传递
The exploration of quantum dot-molecular beacon based MoS_(2) fluorescence probing for myeloma-related Mirnas detection
2
作者 Jing Jing Wang Ying Liu +9 位作者 Zhou Ding Le Zhang Caiqin Han changchun yan Eric Amador Liqin Yuan Ying Wu Chunyuan Song Ying Liu Wei Chen 《Bioactive Materials》 SCIE 2022年第11期360-368,共9页
Highly sensitive and reliable detection of multiple myeloma remains a major challenge in liquid biopsy. Herein, for the first time, quantum dot-molecular beacon (QD-MB) functionalized MoS_(2) (QD-MB @MoS_(2)) fluoresc... Highly sensitive and reliable detection of multiple myeloma remains a major challenge in liquid biopsy. Herein, for the first time, quantum dot-molecular beacon (QD-MB) functionalized MoS_(2) (QD-MB @MoS_(2)) fluorescent probes were designed for the dual detection of multiple myeloma (MM)-related miRNA-155 and miRNA-150. The results indicate that the two probes can effectively detect miRNA-155 and miRNA-150 simultaneously with satisfactory recovery rates, and the limit of detections (LODs) of miRNA-155 and miRNA-150 in human serum are low to 7.19 fM and 5.84 fM, respectively. These results indicate that our method is the most sensitive detection so far reported and that the designed fluorescent probes with signal amplification strategies can achieve highly sensitive detection of MM-related miRNAs for MM diagnosis. 展开更多
关键词 Multiple myeloma miRNA-155 miRNA-150 Duplex-specific nuclease(DSN) Quantum dot MoS_(2) Molecular beacon
原文传递
Goos–H?nchen shifts in reflective phase-gradient-produced metasurfaces
3
作者 Junxian Shi Jingshan qi +2 位作者 Linyong qian Caiqin Han changchun yan 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第6期73-77,共5页
We studied Goos–H?nchen(GH) shifts on a reflective phase-gradient-produced metasurface. Their analytical solutions were achieved for both TE and TM polarizations utilizing the generalized Snell's law. The calcula... We studied Goos–H?nchen(GH) shifts on a reflective phase-gradient-produced metasurface. Their analytical solutions were achieved for both TE and TM polarizations utilizing the generalized Snell's law. The calculated results show that the GH shifts are evidently affected by phase gradients and incident angles, which means that a certain range of GH shifts can be realized as long as an incident angle, phase gradient, and frequency are properly chosen. This offers an effective method for the control of GH shifts. 展开更多
关键词 GH H?nchen shifts in reflective phase-gradient-produced metasurfaces
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部