We aimed to establish for the rapid detection of morphine,O6‑monoacetylmorphine,heroin,codeine,cocaine,methamphetamine,ketamine,methadone,and dolantin in human blood and urine by direct analysis in real‑time coupled w...We aimed to establish for the rapid detection of morphine,O6‑monoacetylmorphine,heroin,codeine,cocaine,methamphetamine,ketamine,methadone,and dolantin in human blood and urine by direct analysis in real‑time coupled with tandem mass spectrometry(DART‑MS/MS).These samples were extracted by acetonitrile‑methanol(V/V=4:1),using DART 12 Dip‑it automatic sampling system.They were injected at 400℃,and analyzed by positive ion and multiple reaction monitoring mode.The detection limits of morphine,O6‑Monoacetylmorphine,heroin,codeine,cocaine,methamphetamine,ketamine,methadone,and dolantin were 100,50,50,100,20,20,10,1,and 0.01 ng/mL,respectively.The practical cases contained methamphetamine,codeine,cocaine,and O6‑monoacetylmorphine were detected accurately and rapidly.The method has the advantages of high sensitivity and good accuracy.The sample processing is simple and can be analyzed in a short time.This method is suitable for the analysis of morphine,O6‑monoacetylmorphine,heroin,codeine,cocaine,methamphetamine,ketamine,methadone,and dolantin in some practical cases.展开更多
基金This research was supported by the Project for Strengthening the Police Force with Science and Technology(project number 2018GABJC29).
文摘We aimed to establish for the rapid detection of morphine,O6‑monoacetylmorphine,heroin,codeine,cocaine,methamphetamine,ketamine,methadone,and dolantin in human blood and urine by direct analysis in real‑time coupled with tandem mass spectrometry(DART‑MS/MS).These samples were extracted by acetonitrile‑methanol(V/V=4:1),using DART 12 Dip‑it automatic sampling system.They were injected at 400℃,and analyzed by positive ion and multiple reaction monitoring mode.The detection limits of morphine,O6‑Monoacetylmorphine,heroin,codeine,cocaine,methamphetamine,ketamine,methadone,and dolantin were 100,50,50,100,20,20,10,1,and 0.01 ng/mL,respectively.The practical cases contained methamphetamine,codeine,cocaine,and O6‑monoacetylmorphine were detected accurately and rapidly.The method has the advantages of high sensitivity and good accuracy.The sample processing is simple and can be analyzed in a short time.This method is suitable for the analysis of morphine,O6‑monoacetylmorphine,heroin,codeine,cocaine,methamphetamine,ketamine,methadone,and dolantin in some practical cases.