Thin-film microextraction(TFME),a new geometry for solid-phase microextraction,has become an attractive sample-preparation technique.Compared to other microextraction approaches,the sensitivity of this technique was...Thin-film microextraction(TFME),a new geometry for solid-phase microextraction,has become an attractive sample-preparation technique.Compared to other microextraction approaches,the sensitivity of this technique was enhanced without sacrificing the sampling time due to the high surface area-tovolume ratio together with the increase of extraction-phase volume.In this paper,a new TFME method based on poly(vinylidene fluoride) membrane was developed for the extraction of benzoylurea insecticides(diflubenzuron,triflumuron,hexaflumuron and teflubenzuron) from water samples followed by their determination with high performance liquid chromatography-diode array detection.Under the optimal conditions,good linearity was observed over the concentration range of 0.5-100.0 ng/mL with correlation coefficient greater than 0.9994.The limits of detection(S/N = 3) of the method for the target analytes were 0.1 ng/mL.Mean recoveries ranged from 87.7% to 103.9% with relative standard deviations lower than 6.5%.The results indicated that the developed TFME method is simple,efficient,and cost effective.展开更多
基金Financial supports from the National Natural Science Foundation of China(No.31171698)the Innovation Research Program of Department of Education of Hebei for Hebei Provincial Universities (No.LJRC009)+1 种基金the Scientific and Technological Research Foundation of Department of Education of Hebei Province(No. ZD20131033)the Natural Science Foundation of Hebei(No. B2012204028)
文摘Thin-film microextraction(TFME),a new geometry for solid-phase microextraction,has become an attractive sample-preparation technique.Compared to other microextraction approaches,the sensitivity of this technique was enhanced without sacrificing the sampling time due to the high surface area-tovolume ratio together with the increase of extraction-phase volume.In this paper,a new TFME method based on poly(vinylidene fluoride) membrane was developed for the extraction of benzoylurea insecticides(diflubenzuron,triflumuron,hexaflumuron and teflubenzuron) from water samples followed by their determination with high performance liquid chromatography-diode array detection.Under the optimal conditions,good linearity was observed over the concentration range of 0.5-100.0 ng/mL with correlation coefficient greater than 0.9994.The limits of detection(S/N = 3) of the method for the target analytes were 0.1 ng/mL.Mean recoveries ranged from 87.7% to 103.9% with relative standard deviations lower than 6.5%.The results indicated that the developed TFME method is simple,efficient,and cost effective.