期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Segmental radiofrequency ablation of pulmonary vein ostia for patients with refractory paroxysmal atrial fibrillation using multi-slice spiral computed tomography guidance 被引量:6
1
作者 JIANG chen-yang(蒋晨阳) +7 位作者 WANG Jian-an(王建安) HE Hong(何红) SUN Yong(孙勇) ZHOU Bin-quan(周斌全) 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2005年第12期1153-1156,共4页
Objective: To evaluate the safety and clinical efficacy of segmental radiofrequency ablation of pulmonary vein (PV)ostia for patients with refractory paroxysmal atrial fibrillation (AF) under multi-slice spiral comput... Objective: To evaluate the safety and clinical efficacy of segmental radiofrequency ablation of pulmonary vein (PV)ostia for patients with refractory paroxysmal atrial fibrillation (AF) under multi-slice spiral computed tomography (MSCT)guidance before the procedure. Methods: A series of 58 consecutive patients with refractory paroxysmal AF were enrolled to undergo segmental radiofrequency ablation ofPV ostia. The 36 male and 22 female patients with mean age of (57.4±9.5) (32~79)atrium (LA) and proximal PVs. Patients then underwent segmental radiofrequency ablation of PV ostia using PV circular mapping catheter manipulated several times to ensure complete isolation between PVs and LA. Results: No complications occurred during the procedure. One patient developed delayed cardiac tamponade, which was drained percutaneously. The mean follow-up time was (17.1±9.3) months. Forty-one patients (95%) experienced improved quality of life one month after the procedure. Thirty-six patients (83%) showed stable sinus rhythm, while 10 patients (23%) required additional anti-arrhythmic drugs. AF returned≥1time in 6 (14%) patients who underwent anti-arrhythmic drug therapy, but the number of episodes was less than that before the procedure. However, one patient experienced recurrent episodes of atrial flutter. Conclusion: It is safe and effective to perform segmental radiofrequency ablation of PV ostia for patients with refractory paroxysmal AF using MSCT guidance mappening. 展开更多
关键词 心室纤维颤动 肺静脉 消融术 X线断层摄影术 治疗方法
下载PDF
Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients
2
作者 DONG Liang(董樑) +3 位作者 WANG Jian-an(王建安) JIANG chen-yang(蒋晨阳) 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2005年第12期1157-1162,共6页
Objective: To compare a new device (Innocor) for non-invasive measurement of cardiac output (CO) by foreign gas rebreathing method with conventional techniques used in the measurements of cardiac function. Methods: Ca... Objective: To compare a new device (Innocor) for non-invasive measurement of cardiac output (CO) by foreign gas rebreathing method with conventional techniques used in the measurements of cardiac function. Methods: Cardiac outputs measured by Innocor (CORB) were compared with CO obtained by echocardiography (COEC), Swan-Ganz thermodilution (COTD), and left ventricle radiography (COLVR) in 34 patients subjected to cardiac catheterization. Values obtained from the four methods were analyzed by linear regression and paired values were compared by the method of Bland and Altman in SPSS. Results: There was strong positive correlation (r=0.94) between Innocor cardiac output values and the corresponding values obtained by ther-modilution and between COEC and COLVR values. Thermodilution appears to overestimate cardiac output when compared to the values obtained with Innocor by (0.66±0.22) L/min (P<0.0001). There was no correlation between data obtained by Innocor and the corresponding COEC and COLVR values. Conclusion: Innocor CORB is an easy, safe and well established method for non-invasive measurement of cardiac output with good prospects for clinical application in heart disease patients. 展开更多
关键词 心脏疾病 冠状动脉 心室 超声波心动描记术 诊断方法
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部