期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Total hip replacement using MINIMA^(■)short stem:A short-term follow-up study 被引量:1
1
作者 Georgios I Drosos Stylianos Tottas +3 位作者 Ioannis Kougioumtzis Konstantinos Tilkeridis christos chatzipapas Athanasios Ververidis 《World Journal of Orthopedics》 2020年第4期232-242,共11页
BACKGROUND Total hip replacement has become one of the most successful orthopaedic procedures.The length of the femoral stem constitutes one of the most important geometrical and mechanical features of the prosthesis.... BACKGROUND Total hip replacement has become one of the most successful orthopaedic procedures.The length of the femoral stem constitutes one of the most important geometrical and mechanical features of the prosthesis.Several different implants are currently available but data are limited concerning the clinical results for some of these implants.AIM To report the short-term clinical and radiological results of a novel squared section,tapered design–with four conicity-short stem in total hip replacement.METHODS This is a retrospective study of a prospectively collected data using of MINIMA?short stem in 61 consecutive patients with at least 1 year follow-up.The collected data included patients’demographics,type of arthritis,bone morphology,perioperative data,clinical results using Harris Hip Score,EuroQol(EQ-5D),pain score and satisfaction rate,complications and radiological results.RESULTS Total 61 patients were included in our study with a mean age of 56 years of age(range 25-73 years).The majority of them(68.6%)were women,thirty seven patients(56.9%)were less than 60 years of age and almost half of patients(45.1%)suffered from secondary osteoarthritis(hip dysplasia,osteonecrosis,etc.).The mean time of follow-up examination was 33.4 mo(2.8 years)with a range of 12-57 months(1-4.8 years).In 35 patients(56.9%)the follow-up examination was more than 3 years.No major complications such as revision,periprosthetic fracture,dislocation or infection were presented.Re-admission 90 d postoperatively or laterwas deemed unnecessary for any reason regarding the operation.Respectively,the mean pain score,mean Harris hip score,and mean EQ-5D were improved from 6.3,58.7 and 77.3 preoperatively to 0.1,95.1,and 79.8 postoperatively.The Satisfaction rate at the final follow-up was 9.9(SD 0.3,range 8.0-10.0).All stems were classified as stable bone ingrowth and no radiolucent lineswere revealed in any of the modified Gruens’zone at the postoperative Xrays.Stem subsidence was within acceptable limits and the incidence of distal cortical hypertrophy was relatively low.CONCLUSION The clinical and radiological results concerning the MINIMA?short stem are excellent according to this first report of this specific design of the short femoral stems.Because of the small number of cases and short-term follow-up of this study,a longer follow up time and more patients’enrollment is required. 展开更多
关键词 Total hip replacement Total hip arthroplasty Short-stem Hip prostheses Femoral components MINIMA^(■) stem
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部