Nonlinear finite element analysis of three implant-abutment interface designs 被引量:3
1
作者 chun-bo tang Si-Yu Liu +4 位作者 Guo-Xing Zhou Jin-Hua Yu Guang-Dong Zhang Yi-Dong Baot Qiu-Ju Wang 《International Journal of Oral Science》 SCIE CAS CSCD 2012年第2期101-108,共8页
The objective of this study was to investigate the mechanical characteristics of implant-abutment interface design in a dental implant system, using nonlinear finite element analysis (FEA) method. This finite elemen... The objective of this study was to investigate the mechanical characteristics of implant-abutment interface design in a dental implant system, using nonlinear finite element analysis (FEA) method. This finite element simulation study was applied on three commonly used commercial dental implant systems: model I, the reduced-diameter 3i implant system (West Palm Beach, FL, USA) with a hex and a 12-point double internal hexagonal connection; model II, the Semados implant system (Bego, Bremen, Germany) with combination of a conical (45° taper) and internal hexagonal connection; and model III, the Br,~nemark implant system (Nobel Biocare, Gothenburg, Sweden) with external hexagonal connection. In simulation, a force of 170 N with 45°oblique to the longitudinal axis of the implant was loaded to the top surface of the abutment. It has been found from the strength and stiffness analysis that the 3i implant system has the lowest maximum yon Mises stress, prirlcipal stress and displacement, while the Br^nemark implant system has the highest. It was concluded from our preliminary study using nonlinear FEA that the reduced-diameter 3i implant system with a hex and a 12-point double internal hexagonal connection had a better stress distribution, and produced a smaller displacement than the other two implant systems. 展开更多
关键词 external hexagonal connection finite element analysis implant-abutment interface internal hexagonal connection non-linear analysis
下载PDF
超声造影在经皮肾镜取石术后出血监测中的应用
2
作者 秦祥成 汤春波 +3 位作者 周酉枫 齐勇 汪静娜 周永 《中国内镜杂志》 2022年第5期69-73,共5页
目的探讨超声造影(CEUS)在经皮肾镜取石术(PCNL)后出血监测中的应用价值。方法收集2017年8月-2020年9月该院泌尿外科完成PCNL的患者1141例,回顾性分析22例根据临床病情需要行床旁CEUS并接受超选择性肾动脉栓塞术的患者的临床资料。结果1... 目的探讨超声造影(CEUS)在经皮肾镜取石术(PCNL)后出血监测中的应用价值。方法收集2017年8月-2020年9月该院泌尿外科完成PCNL的患者1141例,回顾性分析22例根据临床病情需要行床旁CEUS并接受超选择性肾动脉栓塞术的患者的临床资料。结果1141例PCNL后因肾出血经保守治疗无效需行超选择性肾动脉栓塞术的共22例,发生率为1.93%。CEUS常规应用于PCNL后监测,术后第3天发现肾出血1例,术后第5天发现肾出血12例,术后第8天发现肾出血4例,术后第11天发现肾出血3例,术后第14天发现肾出血1例;1例术后第1天发生严重出血行介入失败,转开放手术。CEUS显示:肾假性动脉瘤15例,肾假性动脉瘤合并动静脉瘘5例,动静脉瘘1例,肾包膜下弥漫出血1例,与数字减影血管造影(DSA)检查相符。结论CEUS可随时、重复监测PCNL后的出血情况,明确肾内有无假性动脉瘤和(或)动静脉瘘,为及时采用超选择性肾动脉栓塞术治疗肾出血提供了临床诊断和治疗依据,并可作为患者术后随诊检查的首选。 展开更多
关键词 超声造影 肾出血 经皮肾镜取石术 肾假性动脉瘤 动静脉瘘
下载PDF