It is essential to continuously and non-invasively monitor the cardiac pumping function in clinical setting. Thus, the study aimed to explore a regional impedance phethysmographic method to assess the changes in strok...It is essential to continuously and non-invasively monitor the cardiac pumping function in clinical setting. Thus, the study aimed to explore a regional impedance phethysmographic method to assess the changes in stroke volume. To do this, we developed a plethysmographic device that was capable of delivering a single-frequency current with constant amplitude and of recording electrical impedance signals of biological tissue. The electrical impedance plethy- smographic waveform form the lower arm was measured with the impedance plethysmographic device, and simultaneously the end-systolic and end- diastolic volumes of the left ventricle were obtained with a two-dimension echocardiographic system in fourteen healthy subjects before and immediately after a thirty-second breath-hold maneuver. For the 14 subjects, a linear correlation coefficient of 0.79 (p < 0.001) was obtained between the changes in peak amplitude of the forearm impedance waveform and the changes in stroke volume before and just after the breath-hold test. In addition, the changes in the mean area under the impedance curve and the change in stroke volume were also correlated linearly (r = 0.71, p < 0.005). In summary, the forearm impedance plethysmography may be employed to evaluate the beat-to-beat alteration in cardiac stroke volume, suggesting its potential for long-term monitoring cardiac pumping performance.展开更多
To investigate the worn-surface microstructure and fatigue cracks in D2 wheel steel under the pure rolling and 0.5% slip ratio conditions,a rolling wear test using a GPM-40 wear machine to simulate the wheel/rail oper...To investigate the worn-surface microstructure and fatigue cracks in D2 wheel steel under the pure rolling and 0.5% slip ratio conditions,a rolling wear test using a GPM-40 wear machine to simulate the wheel/rail operation was performed. After testing,a transmission electron microscope,a scanning electron microscope with electron backscatter diffraction,and micro-hardness testers were used to characterize the microstructure and fatigue cracks.The surface microstrncture and hardness of the pure rolling sample were in a steady state after 8 × 10^4 cycles;however,the 0.5% slip ratio sample reached a steady state after 7 × 10^3 cycles.Regardless of whether the test uses the slip ratio,the orientation of lamellar pearlites gradually became parallel to the surface and a portion of lamellar cementites was fragmented and dissolved during the formation of steady-state microstructure.The slip ratio accelerates this process.The hardening mechanism of the samples shows a decrease in the lamellar spacing of pearlite and the refinement of proeutectoid ferrite (PF).As the number of cycles increased,plastic deformation of samples became increasingly severe and the wear mechanism of the samples was fatigue wear in steady state.The sample surfaces formed shallow cracks,which gradually peeled off.The slip ratio accelerated the initiation and propagation of fatigue cracks because of the high friction stress on the contact surface.Most fatigue cracks initiated at the interface of pearlite and PF and in the PF region.展开更多
文摘It is essential to continuously and non-invasively monitor the cardiac pumping function in clinical setting. Thus, the study aimed to explore a regional impedance phethysmographic method to assess the changes in stroke volume. To do this, we developed a plethysmographic device that was capable of delivering a single-frequency current with constant amplitude and of recording electrical impedance signals of biological tissue. The electrical impedance plethy- smographic waveform form the lower arm was measured with the impedance plethysmographic device, and simultaneously the end-systolic and end- diastolic volumes of the left ventricle were obtained with a two-dimension echocardiographic system in fourteen healthy subjects before and immediately after a thirty-second breath-hold maneuver. For the 14 subjects, a linear correlation coefficient of 0.79 (p < 0.001) was obtained between the changes in peak amplitude of the forearm impedance waveform and the changes in stroke volume before and just after the breath-hold test. In addition, the changes in the mean area under the impedance curve and the change in stroke volume were also correlated linearly (r = 0.71, p < 0.005). In summary, the forearm impedance plethysmography may be employed to evaluate the beat-to-beat alteration in cardiac stroke volume, suggesting its potential for long-term monitoring cardiac pumping performance.
文摘To investigate the worn-surface microstructure and fatigue cracks in D2 wheel steel under the pure rolling and 0.5% slip ratio conditions,a rolling wear test using a GPM-40 wear machine to simulate the wheel/rail operation was performed. After testing,a transmission electron microscope,a scanning electron microscope with electron backscatter diffraction,and micro-hardness testers were used to characterize the microstructure and fatigue cracks.The surface microstrncture and hardness of the pure rolling sample were in a steady state after 8 × 10^4 cycles;however,the 0.5% slip ratio sample reached a steady state after 7 × 10^3 cycles.Regardless of whether the test uses the slip ratio,the orientation of lamellar pearlites gradually became parallel to the surface and a portion of lamellar cementites was fragmented and dissolved during the formation of steady-state microstructure.The slip ratio accelerates this process.The hardening mechanism of the samples shows a decrease in the lamellar spacing of pearlite and the refinement of proeutectoid ferrite (PF).As the number of cycles increased,plastic deformation of samples became increasingly severe and the wear mechanism of the samples was fatigue wear in steady state.The sample surfaces formed shallow cracks,which gradually peeled off.The slip ratio accelerated the initiation and propagation of fatigue cracks because of the high friction stress on the contact surface.Most fatigue cracks initiated at the interface of pearlite and PF and in the PF region.