A performance study of several CCD cameras of the Chinese Joint Laboratory of Optical Astronomy (CJLOA) is presented. The main results are: 1) We propose a modified classical method to analyse the linearity of CCD cam...A performance study of several CCD cameras of the Chinese Joint Laboratory of Optical Astronomy (CJLOA) is presented. The main results are: 1) We propose a modified classical method to analyse the linearity of CCD cameras. This method is more sensitive and accurate as well as more intuitive, especially in measuring around the 0.1%-0.2% range of nonlinearity. 2) To illustrate the advantage of the method, the linearity performance of the CCD cameras at CJLOA has been measured and analysed. 3) For the CCD systems tested, there is no unique formula to represent the correlation over the entire CCD frame between the deviation from linearity and the pixel value, i.e., different pixel has different correction even though their pixel values are the same. 4) For the BFOSC (BAO Faint Object Spectrograph Camera) Loral CCD camera and the Tek CCD camera at the 1.56-m reflector, blooming (bleeding) happens long before saturation, and we suspect whether it could have resulted from the charge transfer efficiency (CTE) not being high enough.展开更多
Abstract In this paper we consider the risk process that is described by a piecewise deterministic Markov processes (PDMP). We first present the construction of the risk process and then discuss some ruin problems for...Abstract In this paper we consider the risk process that is described by a piecewise deterministic Markov processes (PDMP). We first present the construction of the risk process and then discuss some ruin problems for this new kind of risk model.展开更多
文摘A performance study of several CCD cameras of the Chinese Joint Laboratory of Optical Astronomy (CJLOA) is presented. The main results are: 1) We propose a modified classical method to analyse the linearity of CCD cameras. This method is more sensitive and accurate as well as more intuitive, especially in measuring around the 0.1%-0.2% range of nonlinearity. 2) To illustrate the advantage of the method, the linearity performance of the CCD cameras at CJLOA has been measured and analysed. 3) For the CCD systems tested, there is no unique formula to represent the correlation over the entire CCD frame between the deviation from linearity and the pixel value, i.e., different pixel has different correction even though their pixel values are the same. 4) For the BFOSC (BAO Faint Object Spectrograph Camera) Loral CCD camera and the Tek CCD camera at the 1.56-m reflector, blooming (bleeding) happens long before saturation, and we suspect whether it could have resulted from the charge transfer efficiency (CTE) not being high enough.
基金Supported by the National Natural Sciences Foundation of China (No.19971047)Doctoral Foundation of Suzhou University.
文摘Abstract In this paper we consider the risk process that is described by a piecewise deterministic Markov processes (PDMP). We first present the construction of the risk process and then discuss some ruin problems for this new kind of risk model.