This paper presents a comparison and analysis method of data at traffic meteorological observation station during Beijing Winter Olympic Games period based on Grubbs criterion. By comparing the data of a set of standa...This paper presents a comparison and analysis method of data at traffic meteorological observation station during Beijing Winter Olympic Games period based on Grubbs criterion. By comparing the data of a set of standard multi-element observation stations with the data of multiple measured traffic stations, the outliers of each element data at each station were analyzed. It could provide data support for the maintenance of Zhangjiakou traffic meteorological observation station and a guarantee for the accuracy of forest service during Beijing Winter Olympic Games period.展开更多
According to the verification regulation of the Wind Direction and Wind Speed Sensor of Automatic Meteorological Station[JJG(meteorological)004-2011],relying on the wind tunnel laboratory of Hebei meteorological measu...According to the verification regulation of the Wind Direction and Wind Speed Sensor of Automatic Meteorological Station[JJG(meteorological)004-2011],relying on the wind tunnel laboratory of Hebei meteorological measurement station,EL15-1 A type of wind speed sensor in the automatic weather station was verified.The experimental data of sensor verification in different laboratory environments were obtained through data comparison.Using standard wind speed measurement formula,the influence of laboratory temperature,humidity and air pressure on verification results was analyzed quantitatively.The results showed that laboratory temperature had the greatest influence on the verification results of this type of sensor,while the humidity and air pressure had less influence.Therefore,it should be noted that the temperature change in the laboratory should not be too large in the process of verification,so as to improve the accuracy of the verification results.展开更多
At present,the verification system of wind speed in national 3MS provincial automatic weather station has been automated,but the wind speed verification of the DEM6 portable three-cup anemometer by the straight road w...At present,the verification system of wind speed in national 3MS provincial automatic weather station has been automated,but the wind speed verification of the DEM6 portable three-cup anemometer by the straight road wind tunnel cannot be automated.In order to record the reading of this verification,it is necessary to manually move the starting lever at the wind speed field during each verification.For this problem,a set of verification device for the DEM6 portable three-cup anemometer is developed based on automatic verification system of wind speed in the 3MS provincial automatic weather station.This device uses the the driving board of starting anemometer to connect with the pressing starting lever by a bar-shaped gap,so as to realize the remote control of the starting lever.It is convenient to use,and measure multiple sets of data at the same place.The measuring results are more accurate,thereby realizing automatic pressing of wind speed starting lever.展开更多
文摘This paper presents a comparison and analysis method of data at traffic meteorological observation station during Beijing Winter Olympic Games period based on Grubbs criterion. By comparing the data of a set of standard multi-element observation stations with the data of multiple measured traffic stations, the outliers of each element data at each station were analyzed. It could provide data support for the maintenance of Zhangjiakou traffic meteorological observation station and a guarantee for the accuracy of forest service during Beijing Winter Olympic Games period.
文摘According to the verification regulation of the Wind Direction and Wind Speed Sensor of Automatic Meteorological Station[JJG(meteorological)004-2011],relying on the wind tunnel laboratory of Hebei meteorological measurement station,EL15-1 A type of wind speed sensor in the automatic weather station was verified.The experimental data of sensor verification in different laboratory environments were obtained through data comparison.Using standard wind speed measurement formula,the influence of laboratory temperature,humidity and air pressure on verification results was analyzed quantitatively.The results showed that laboratory temperature had the greatest influence on the verification results of this type of sensor,while the humidity and air pressure had less influence.Therefore,it should be noted that the temperature change in the laboratory should not be too large in the process of verification,so as to improve the accuracy of the verification results.
文摘At present,the verification system of wind speed in national 3MS provincial automatic weather station has been automated,but the wind speed verification of the DEM6 portable three-cup anemometer by the straight road wind tunnel cannot be automated.In order to record the reading of this verification,it is necessary to manually move the starting lever at the wind speed field during each verification.For this problem,a set of verification device for the DEM6 portable three-cup anemometer is developed based on automatic verification system of wind speed in the 3MS provincial automatic weather station.This device uses the the driving board of starting anemometer to connect with the pressing starting lever by a bar-shaped gap,so as to realize the remote control of the starting lever.It is convenient to use,and measure multiple sets of data at the same place.The measuring results are more accurate,thereby realizing automatic pressing of wind speed starting lever.