The photoelectric device of a scintillation dosimeter converts photons produced by radiation into an electrical signal.Its features directly determine the overall performance of the dosimeter.For a plastic scintillati...The photoelectric device of a scintillation dosimeter converts photons produced by radiation into an electrical signal.Its features directly determine the overall performance of the dosimeter.For a plastic scintillation fiber dosimeter(PSFD)with a current readout mode,systematic studies of the stability and light-dose response were performed for the photomultiplier tube(PMT),silicon photomultiplier(SiPM),avalanche photodiode(APD),and photodiode(PD).The temperature stability,long-term stability,repeatability,signal-to-noise ratio(SNR),and current dose response of the PSFD with the abovementioned photoelectric devices were studied using a pulsed LED light source and the Small Animal Radiation Therapy platform.An exponential relationship between the dark/ne current and temperature was obtained for all the devices.I is shown that the APD is the most sensitive device to temperature,with a current dependence on temperature reaching 6.5%C^(-1)at room temperature,whereas for the other devices this dependence is always<0:6%C^(-1).In terms of long-term stability,the net current of PD can change by up to 4%when working continuously for 8 h and 2%when working intermittently for 32 h,whereas for the other devices,the changes are all<1%.For the dose response,the PMT and SiPM exhibit excellent linear responses and SNRs within the range of 0.1-60 Gy/min For the PSFD with a current readout mode,the performance of the PMT and SiPM is concluded to be better than that of the other devices in the study.In particular,the SiPM,which has a compact size,low bias voltage,and antimagnetic interference,has great advantages for further applications.展开更多
Interventional radiology has been beneficial for patients for over 30 years of age with the combination of diagnostic and therapeutic methods. The radiation affecting occupationally exposed workers should be evaluated...Interventional radiology has been beneficial for patients for over 30 years of age with the combination of diagnostic and therapeutic methods. The radiation affecting occupationally exposed workers should be evaluated by means of the energy spectra and flux of X-rays in the treatment room. The present study aims to obtain the energy spectra of interventional procedures and study the capability of some detectors to evaluate the dose in interventional procedures. These measurements were taken by silicon-drift, CdTe, and CdZnTe detectors. The energy spectra were corrected by the energy-response curve of each detector. The energy-response curves of silicon-drift and CdTe detectors provided by the manufacturers specification were used. The energy response of the CdZnTe detector was measured by 133Ba and 152Eu γ sources. The experimental data were compared with the simulation results, and their perfect agreement provides a way to correct the energy or dose response, which can be used for the personal dosimeter developed by our group. Moreover, the measured energy spectra can be used in individual radiation protection. The present study shows that the CdZnTe detector is a good candidate detector in interventional procedures.展开更多
Basal cell carcinoma (BCC) is the most common skin cancer worldwide, with incidence rates continuing to increase. Ultraviolet radiation is the major environmental risk factor and dysregulation of the Hedgehog (Hh)...Basal cell carcinoma (BCC) is the most common skin cancer worldwide, with incidence rates continuing to increase. Ultraviolet radiation is the major environmental risk factor and dysregulation of the Hedgehog (Hh) signaling pathway has been identified in most BCCs. The treatment of locally advanced and metastatic BBCs is still a challenge and requires a better animal model than the widely used rodents for drug development and testing. Chinese tree shrews (Tupaia belangeri chinensis) are closely related to primates, bearing many physiological and biochemical advantages over rodents for characterizing human diseases. Here, we successfully established a Chinese tree shrew BCC model by infecting tail skins with lentiviral SmoA1, an active form of Smoothened (Smo) used to constitutively activate the Hh signaling pathway. The pathological characteristics were verified by immunohistochemical analysis. Interestingly, BCC progress was greatly enhanced by the combined usage of lenUviral SmoA1 and shRNA targeting Chinese tree shrew p53. This work provides a useful animal model for further BCC studies and future展开更多
In the shaping process of cross wedge rolling(CWR), metal undergoes a complex microstructural evolution, which affects the quality and mechanical properties of the product. Through secondary development of the DEFOR...In the shaping process of cross wedge rolling(CWR), metal undergoes a complex microstructural evolution, which affects the quality and mechanical properties of the product. Through secondary development of the DEFORM-3D software, we developed a rigid plastic finite element model for a CWR-processed rear axle tube, coupled with thermomechanical and microstructural aspects of workpieces. Using the developed model, we investigated the microstructural evolution of the CWR process. Also, the influence of numerous parameters, including the initial temperature of workpieces, the roll speed, the forming angle, and the spreading angle, on the grain size and the grain-size uniformity of the rolled workpieces was analyzed. The numerical simulation was verified through rolling and metallographic experiments. Good agreement was obtained between the calculated and experimental results, which demonstrated the reliability of the model constructed in this work.展开更多
基金financially supported by the National Natural Science Foundation of China(Nos.52071347,51971205)the Innovation Group Project of Southern Marine Science and Engineering Guangdong Laboratory(Zhuhai),China(No.311020012)。
基金supported by the China Postdoctoral Science Foundation(No.2017M621818)the National Key Research and Development Project(Nos.2017YFF0206205 and2016YFB0501303)+1 种基金the National Natural Science Foundation of China(Nos.51873137 and 11705123)the Project of the State Key Laboratory of Radiation Medicine and Protection Soochow University(No.GZN1201801)。
文摘The photoelectric device of a scintillation dosimeter converts photons produced by radiation into an electrical signal.Its features directly determine the overall performance of the dosimeter.For a plastic scintillation fiber dosimeter(PSFD)with a current readout mode,systematic studies of the stability and light-dose response were performed for the photomultiplier tube(PMT),silicon photomultiplier(SiPM),avalanche photodiode(APD),and photodiode(PD).The temperature stability,long-term stability,repeatability,signal-to-noise ratio(SNR),and current dose response of the PSFD with the abovementioned photoelectric devices were studied using a pulsed LED light source and the Small Animal Radiation Therapy platform.An exponential relationship between the dark/ne current and temperature was obtained for all the devices.I is shown that the APD is the most sensitive device to temperature,with a current dependence on temperature reaching 6.5%C^(-1)at room temperature,whereas for the other devices this dependence is always<0:6%C^(-1).In terms of long-term stability,the net current of PD can change by up to 4%when working continuously for 8 h and 2%when working intermittently for 32 h,whereas for the other devices,the changes are all<1%.For the dose response,the PMT and SiPM exhibit excellent linear responses and SNRs within the range of 0.1-60 Gy/min For the PSFD with a current readout mode,the performance of the PMT and SiPM is concluded to be better than that of the other devices in the study.In particular,the SiPM,which has a compact size,low bias voltage,and antimagnetic interference,has great advantages for further applications.
基金supported by the National Natural Science Foundation of China(No.11705123)Natural Science Foundation of Jiangsu Province(No.BK20160306)+1 种基金China Postdoctoral Science Foundation(No.2016M591911)the Project of the State Key Laboratory of Radiation Medicine and Protection,Soochow University(No.GZN1201801)
文摘Interventional radiology has been beneficial for patients for over 30 years of age with the combination of diagnostic and therapeutic methods. The radiation affecting occupationally exposed workers should be evaluated by means of the energy spectra and flux of X-rays in the treatment room. The present study aims to obtain the energy spectra of interventional procedures and study the capability of some detectors to evaluate the dose in interventional procedures. These measurements were taken by silicon-drift, CdTe, and CdZnTe detectors. The energy spectra were corrected by the energy-response curve of each detector. The energy-response curves of silicon-drift and CdTe detectors provided by the manufacturers specification were used. The energy response of the CdZnTe detector was measured by 133Ba and 152Eu γ sources. The experimental data were compared with the simulation results, and their perfect agreement provides a way to correct the energy or dose response, which can be used for the personal dosimeter developed by our group. Moreover, the measured energy spectra can be used in individual radiation protection. The present study shows that the CdZnTe detector is a good candidate detector in interventional procedures.
基金supported by the National Key Research and Development Program of China(2016YFA0100900)the Strategic Priority Research Program of the Chinese Academy of Sciences(XDB13000000)+2 种基金the National Nature Science Foundation of China(U1502224,81672764)the Yunnan Applied Basic Research Projects(2014FA038,2016FA009,2014FB182)supported by the Chinese Academy of Sciences Western Light Program,Youth Innovation Promotion Association,CAS
文摘Basal cell carcinoma (BCC) is the most common skin cancer worldwide, with incidence rates continuing to increase. Ultraviolet radiation is the major environmental risk factor and dysregulation of the Hedgehog (Hh) signaling pathway has been identified in most BCCs. The treatment of locally advanced and metastatic BBCs is still a challenge and requires a better animal model than the widely used rodents for drug development and testing. Chinese tree shrews (Tupaia belangeri chinensis) are closely related to primates, bearing many physiological and biochemical advantages over rodents for characterizing human diseases. Here, we successfully established a Chinese tree shrew BCC model by infecting tail skins with lentiviral SmoA1, an active form of Smoothened (Smo) used to constitutively activate the Hh signaling pathway. The pathological characteristics were verified by immunohistochemical analysis. Interestingly, BCC progress was greatly enhanced by the combined usage of lenUviral SmoA1 and shRNA targeting Chinese tree shrew p53. This work provides a useful animal model for further BCC studies and future
基金support given by the National Natural Science Foundation of China (No.51505026)
文摘In the shaping process of cross wedge rolling(CWR), metal undergoes a complex microstructural evolution, which affects the quality and mechanical properties of the product. Through secondary development of the DEFORM-3D software, we developed a rigid plastic finite element model for a CWR-processed rear axle tube, coupled with thermomechanical and microstructural aspects of workpieces. Using the developed model, we investigated the microstructural evolution of the CWR process. Also, the influence of numerous parameters, including the initial temperature of workpieces, the roll speed, the forming angle, and the spreading angle, on the grain size and the grain-size uniformity of the rolled workpieces was analyzed. The numerical simulation was verified through rolling and metallographic experiments. Good agreement was obtained between the calculated and experimental results, which demonstrated the reliability of the model constructed in this work.