期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
电解液成分对等离子体电解氧化TC4合金腐蚀行为和摩擦学性能的影响 被引量:2
1
作者 杨翠萍 孟宪泽 +4 位作者 李鑫冉 李哲轩 严豪杰 伍廉奎 曹发和 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2023年第1期141-156,共16页
在TC4合金表面制备4种典型等离子体电解氧化(PEO)涂层,研究电解质组成对PEO涂层腐蚀行为和摩擦学性能的影响。结果表明,PEO涂层的腐蚀行为和摩擦学性能与电解质成分密切相关。在含NaH_(2)PO_(2)的电解液中制备的PEO涂层由于内氧化膜较... 在TC4合金表面制备4种典型等离子体电解氧化(PEO)涂层,研究电解质组成对PEO涂层腐蚀行为和摩擦学性能的影响。结果表明,PEO涂层的腐蚀行为和摩擦学性能与电解质成分密切相关。在含NaH_(2)PO_(2)的电解液中制备的PEO涂层由于内氧化膜较致密而具有最好的耐蚀性能,而在含NaAlO_(2)的电解液中制备的PEO涂层由于含有Al_(2)O_(3)而具有最好的摩擦学性能。为制备具有良好耐蚀性和耐磨性的PEO涂层,以NaH_(2)PO_(2)和NaAlO_(2)为电解液主要成分制备了复合PEO涂层。 展开更多
关键词 TI6AL4V合金 等离子体电解氧化 极化曲线 磨损
下载PDF
Performance of a plastic scintillation fiber dosimeter based on different photoelectric devices 被引量:3
2
作者 Yue yang cui-ping yang +6 位作者 Jie Xin Hai-Feng Chen Zhong-Xu Xing Wei-Wei Qu Liang Hu Xin-Jian Chen Ren-Sheng Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第11期25-31,共7页
The photoelectric device of a scintillation dosimeter converts photons produced by radiation into an electrical signal.Its features directly determine the overall performance of the dosimeter.For a plastic scintillati... The photoelectric device of a scintillation dosimeter converts photons produced by radiation into an electrical signal.Its features directly determine the overall performance of the dosimeter.For a plastic scintillation fiber dosimeter(PSFD)with a current readout mode,systematic studies of the stability and light-dose response were performed for the photomultiplier tube(PMT),silicon photomultiplier(SiPM),avalanche photodiode(APD),and photodiode(PD).The temperature stability,long-term stability,repeatability,signal-to-noise ratio(SNR),and current dose response of the PSFD with the abovementioned photoelectric devices were studied using a pulsed LED light source and the Small Animal Radiation Therapy platform.An exponential relationship between the dark/ne current and temperature was obtained for all the devices.I is shown that the APD is the most sensitive device to temperature,with a current dependence on temperature reaching 6.5%C^(-1)at room temperature,whereas for the other devices this dependence is always<0:6%C^(-1).In terms of long-term stability,the net current of PD can change by up to 4%when working continuously for 8 h and 2%when working intermittently for 32 h,whereas for the other devices,the changes are all<1%.For the dose response,the PMT and SiPM exhibit excellent linear responses and SNRs within the range of 0.1-60 Gy/min For the PSFD with a current readout mode,the performance of the PMT and SiPM is concluded to be better than that of the other devices in the study.In particular,the SiPM,which has a compact size,low bias voltage,and antimagnetic interference,has great advantages for further applications. 展开更多
关键词 Photoelectric device Plastic scintillation fiber dosimeter(PSFD) Current readout Dose response
下载PDF
Evaluation of CdZnTe spectrometer performance in measuring energy spectra during interventional radiology procedure 被引量:2
3
作者 Lin Chai Lian Chen +7 位作者 cui-ping yang Dong-Dong Zhou Meng-Meng yang Wei-Wei Qu Gao-Long Zhang Da-Qian Hei Shou-Ping Xu Xin-Jian Chen 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第9期55-60,共6页
Interventional radiology has been beneficial for patients for over 30 years of age with the combination of diagnostic and therapeutic methods. The radiation affecting occupationally exposed workers should be evaluated... Interventional radiology has been beneficial for patients for over 30 years of age with the combination of diagnostic and therapeutic methods. The radiation affecting occupationally exposed workers should be evaluated by means of the energy spectra and flux of X-rays in the treatment room. The present study aims to obtain the energy spectra of interventional procedures and study the capability of some detectors to evaluate the dose in interventional procedures. These measurements were taken by silicon-drift, CdTe, and CdZnTe detectors. The energy spectra were corrected by the energy-response curve of each detector. The energy-response curves of silicon-drift and CdTe detectors provided by the manufacturers specification were used. The energy response of the CdZnTe detector was measured by 133Ba and 152Eu γ sources. The experimental data were compared with the simulation results, and their perfect agreement provides a way to correct the energy or dose response, which can be used for the personal dosimeter developed by our group. Moreover, the measured energy spectra can be used in individual radiation protection. The present study shows that the CdZnTe detector is a good candidate detector in interventional procedures. 展开更多
关键词 INTERVENTIONAL RADIOLOGY procedures Energyresponse CURVE Energy spectrum Radiation protection
下载PDF
Establishment of basal cell carcinoma animal model in Chinese tree shrew (Tupaia belangeri chinensis) 被引量:3
4
作者 Li-Ping Jiang Qiu-Shuo Shen +1 位作者 cui-ping yang Yong-Bin Chen 《Zoological Research》 CAS CSCD 2017年第4期180-190,共11页
Basal cell carcinoma (BCC) is the most common skin cancer worldwide, with incidence rates continuing to increase. Ultraviolet radiation is the major environmental risk factor and dysregulation of the Hedgehog (Hh)... Basal cell carcinoma (BCC) is the most common skin cancer worldwide, with incidence rates continuing to increase. Ultraviolet radiation is the major environmental risk factor and dysregulation of the Hedgehog (Hh) signaling pathway has been identified in most BCCs. The treatment of locally advanced and metastatic BBCs is still a challenge and requires a better animal model than the widely used rodents for drug development and testing. Chinese tree shrews (Tupaia belangeri chinensis) are closely related to primates, bearing many physiological and biochemical advantages over rodents for characterizing human diseases. Here, we successfully established a Chinese tree shrew BCC model by infecting tail skins with lentiviral SmoA1, an active form of Smoothened (Smo) used to constitutively activate the Hh signaling pathway. The pathological characteristics were verified by immunohistochemical analysis. Interestingly, BCC progress was greatly enhanced by the combined usage of lenUviral SmoA1 and shRNA targeting Chinese tree shrew p53. This work provides a useful animal model for further BCC studies and future 展开更多
关键词 Chinese lree shrew Basal cell carcinoma HEDGEHOG
下载PDF
Influence of process parameters on the microstructural evolution of a rear axle tube during cross wedge rolling 被引量:3
5
作者 Jia-wei Ma cui-ping yang +2 位作者 Zhen-hua Zheng Kang-sheng Zhang Wen-yu Ma 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2016年第11期1302-1314,共13页
In the shaping process of cross wedge rolling(CWR), metal undergoes a complex microstructural evolution, which affects the quality and mechanical properties of the product. Through secondary development of the DEFOR... In the shaping process of cross wedge rolling(CWR), metal undergoes a complex microstructural evolution, which affects the quality and mechanical properties of the product. Through secondary development of the DEFORM-3D software, we developed a rigid plastic finite element model for a CWR-processed rear axle tube, coupled with thermomechanical and microstructural aspects of workpieces. Using the developed model, we investigated the microstructural evolution of the CWR process. Also, the influence of numerous parameters, including the initial temperature of workpieces, the roll speed, the forming angle, and the spreading angle, on the grain size and the grain-size uniformity of the rolled workpieces was analyzed. The numerical simulation was verified through rolling and metallographic experiments. Good agreement was obtained between the calculated and experimental results, which demonstrated the reliability of the model constructed in this work. 展开更多
关键词 microstructural evolution grain size cross wedge rolling finite element method computer simulation tubes
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部