Battery energy storage stations(BESSs)pose sever-al challenges for both phasor-based differential protection and the newly-proposed time-domain differential protection.These challenges include low sensitivity and even...Battery energy storage stations(BESSs)pose sever-al challenges for both phasor-based differential protection and the newly-proposed time-domain differential protection.These challenges include low sensitivity and even rejection.Besides,the negative impact of various nonideal conditions,including current transformer(CT)saturation,errors,and outliers,on the security of differential protection remains an important problem.Motivated by the aforementioned issues,this study ac-counts for the trajectory distribution discrepancy on Cartesian plane under various conditions and proposes a time-domain dif-ferential protection method.In this paper,the trajectory formed by operating and restraining current samples is devel-oped.Subsequently,after considering different operating states,the fault severity levels,and nonideal conditions,the variances in trajectory distribution between internal and external faults are extensively analyzed.On this basis,the Cartesian plane is divided into operating,uncertainty,and restraining zones.Fur-ther,the operating and restraining trajectory indices are meticu-lously designed and a protection criterion based on these indi-ces is formed to accurately separate internal faults from other events,unaffected by CT saturation,errors,and outliers.The exceptional performance of the proposed protection method is extensively validated through PSCAD simulations and a hard-ware-in-the-loop testing platform.Regarding the dependability,sensitivity,and security,the proposed protection method outper-forms three state-of-the-art differential protection methods.展开更多
基金supported in part by the National Natural Science Foundation of China(No.52277i32)in part by the Fundamental Research Funds for the Central Universities(No.2024JCCXJD01).
文摘Battery energy storage stations(BESSs)pose sever-al challenges for both phasor-based differential protection and the newly-proposed time-domain differential protection.These challenges include low sensitivity and even rejection.Besides,the negative impact of various nonideal conditions,including current transformer(CT)saturation,errors,and outliers,on the security of differential protection remains an important problem.Motivated by the aforementioned issues,this study ac-counts for the trajectory distribution discrepancy on Cartesian plane under various conditions and proposes a time-domain dif-ferential protection method.In this paper,the trajectory formed by operating and restraining current samples is devel-oped.Subsequently,after considering different operating states,the fault severity levels,and nonideal conditions,the variances in trajectory distribution between internal and external faults are extensively analyzed.On this basis,the Cartesian plane is divided into operating,uncertainty,and restraining zones.Fur-ther,the operating and restraining trajectory indices are meticu-lously designed and a protection criterion based on these indi-ces is formed to accurately separate internal faults from other events,unaffected by CT saturation,errors,and outliers.The exceptional performance of the proposed protection method is extensively validated through PSCAD simulations and a hard-ware-in-the-loop testing platform.Regarding the dependability,sensitivity,and security,the proposed protection method outper-forms three state-of-the-art differential protection methods.