Muon tomography is a promising method in the detection and imaging of high Z material. In general, considering the quality of track reconstruction in imaging, a detector of good position resolution, high efficiency an...Muon tomography is a promising method in the detection and imaging of high Z material. In general, considering the quality of track reconstruction in imaging, a detector of good position resolution, high efficiency and large area is required. This paper presents the design and study of a prototype of position sensitive MRPC with 0.15 mm narrow gas gap and 2.54 mm strip readout. Through a cosmic-ray experiment, the performance of MRPC module is carefully observed and each channel is calibrated. Through an X ray experiment with a narrow slit, the position resolution is studied. The results show that the time resolution of the module can reach 61ps and the spatial resolution can reach 0.36 mm.展开更多
基金Supported by National Natural Science Foundation of China(11035002,11020101059,10775082,11275108)
文摘Muon tomography is a promising method in the detection and imaging of high Z material. In general, considering the quality of track reconstruction in imaging, a detector of good position resolution, high efficiency and large area is required. This paper presents the design and study of a prototype of position sensitive MRPC with 0.15 mm narrow gas gap and 2.54 mm strip readout. Through a cosmic-ray experiment, the performance of MRPC module is carefully observed and each channel is calibrated. Through an X ray experiment with a narrow slit, the position resolution is studied. The results show that the time resolution of the module can reach 61ps and the spatial resolution can reach 0.36 mm.