锁模光纤激光器的偏振同步与去同步动力学
1
作者 黄志玮 黄千千 +8 位作者 黄梓楠 李卫淅 戴礼龙 王明娇 代雨泽 王青 闫志君 Sergeyev Sergey 牟成博 《激光与光电子学进展》 CSCD 北大核心 2024年第9期329-335,共7页
基于正色散的非线性偏振旋转(NPR)锁模光纤激光器,在稳定的连续波(CW)锁模状态和复合锁模状态下分析脉冲的偏振特性。通过单一调节泵浦功率,实现稳定的CW锁模状态下耗散孤子(DS)与类噪声(NLP)两种脉冲的切换。另外,固定泵浦功率,仅调节... 基于正色散的非线性偏振旋转(NPR)锁模光纤激光器,在稳定的连续波(CW)锁模状态和复合锁模状态下分析脉冲的偏振特性。通过单一调节泵浦功率,实现稳定的CW锁模状态下耗散孤子(DS)与类噪声(NLP)两种脉冲的切换。另外,固定泵浦功率,仅调节偏振控制器(PCs)可得到由脉冲状态自发切换引起的复合锁模状态。对比分析两种锁模状态下的脉冲偏振特性,发现纵模相位锁定的同步对应于脉冲正交偏振分量的完全同步,纵模相位在同步与去同步切换状态下的复合锁模对应于脉冲正交偏振分量的部分同步。实验结果表明,纵模相位间的同步状态受脉冲正交偏振分量影响。该工作对理解锁模激光器中复杂动力学、发展稳定的激光动力学技术具有指导意义。 展开更多
关键词 锁模光纤激光器 非线性光学 非线性吸引子 光孤子 偏振
原文传递
Performance Analysis of a Combined Absorption Refrigeration-Liquid Desiccant Dehumidification THIC System Driven by Low-Grade Heat Source 被引量:5
2
作者 XU Cong SUI Jun +2 位作者 dai yuze LIU Feng LIU Hao 《Journal of Thermal Science》 SCIE EI CAS CSCD 2020年第5期1193-1205,共13页
Traditional condensing air-conditioning systems consume large amounts of energy in hot and humid areas,and it is difficult to achieve simultaneous control of temperature and humidity.A combined absorption refrigeratio... Traditional condensing air-conditioning systems consume large amounts of energy in hot and humid areas,and it is difficult to achieve simultaneous control of temperature and humidity.A combined absorption refrigeration(AR)and liquid desiccant dehumidification(LDD)air-conditioning system based on cascade utilization of low-grade heat source is proposed.The system can realize independent control of temperature and humidity and carry out profound recovery of low-grade heat sources.Under the design conditions,the heat utilization rate C reaches 21.05%,which is 2.73 times that of the conventional absorption refrigeration reference system.A parametric sensitivity analysis is performed to optimize the system.The C increases from 9.79%to 18.55%and the coefficient of performance C O P t increases from 0.33 to 0.35 with an increase in chilled water temperature from 7°C to 15°C.With an increase in regenerant solution temperature from 60°C to 70°C,the C achieves the optimal value of 21.05%at 68°C.C decreases from 21.05%to 15.05%as the concentration of the regenerant solution increases from 36%to 40%.Under variable environmental temperature and humidity,the C the proposed system changes within a small range and stays much higher than that of the reference system with the same quality heat source,which indicates that the proposed system has a better adaptability to changing environmental parameters. 展开更多
关键词 temperature and humidity independent control(THIC) low-grade heat source cascade utilization heat utilization rate
原文传递