In order to evaluate the imaging quality of COD cameras fully and rapidly, the minimum resolvable contrast (MRC) is presented in this paper and the system of measuring MRC is constructed as well, in which two integr...In order to evaluate the imaging quality of COD cameras fully and rapidly, the minimum resolvable contrast (MRC) is presented in this paper and the system of measuring MRC is constructed as well, in which two integrating spheres are proposed to illuminate two sides of the target respectively. The variable contrast can be obtained by regulating the luminance of integrating spheres. Experimental results indicate that the error of measuring luminance is within ±0.3 cd/m^2 ,MRC rises with the increase of the spatial frequency. The experimental results show that the method proposed is an effective apprcach to evaluate the imaaina aualitv of COD cameras.展开更多
基金Supported by Science and Technology Research Project of Educa-tion Department of Heilongjiang Province(10051065)
文摘In order to evaluate the imaging quality of COD cameras fully and rapidly, the minimum resolvable contrast (MRC) is presented in this paper and the system of measuring MRC is constructed as well, in which two integrating spheres are proposed to illuminate two sides of the target respectively. The variable contrast can be obtained by regulating the luminance of integrating spheres. Experimental results indicate that the error of measuring luminance is within ±0.3 cd/m^2 ,MRC rises with the increase of the spatial frequency. The experimental results show that the method proposed is an effective apprcach to evaluate the imaaina aualitv of COD cameras.