The experiment of CHF (critical heat flux) was conducted for water boiling two-phase flow in three-pin tight rod bundle. The effects of with and without wire spacers and the pitch to diameter ratio p/d on CHF were i...The experiment of CHF (critical heat flux) was conducted for water boiling two-phase flow in three-pin tight rod bundle. The effects of with and without wire spacers and the pitch to diameter ratio p/d on CHF were investigated under the conditions of mass flux range 250-430 kg/(m2·s), inlet temperature from 70 ℃ to 92 ℃ and the pressure of 0.1 MPa. The CHF was enhanced by wire spacers in comparison with the results of CHF without wire spacers. The CHF was enhanced by reducing thep/dfrom 1.18 to 1.10 under the same flow rate condition, although it did not change appreciably with the change ofp/d under the same mass flux condition.展开更多
In order to investigate the coolability of a tight lattice core in BWR (boiling water reactors), an experiment of CHF (critical heat flux) was conducted using a single heater pin flow channel with and without a wi...In order to investigate the coolability of a tight lattice core in BWR (boiling water reactors), an experiment of CHF (critical heat flux) was conducted using a single heater pin flow channel with and without a wire spacer with the mass flux ranged from 200 kg/(m2.s) to 600 kg/(m2·s), the inlet temperature from 50 ℃ to 90 ℃ at the pressure of 0.1 MPa. The results of CHF values were compared between two different types of heater pin with and without the wire spacer. The heat removability of flow channel was improved by the wire spacer in comparison with the heater pin flow channel without the wire spacer. The CHF value was higher in the heater pin channel with the wire spacer than in that without the wire spacer.展开更多
文摘The experiment of CHF (critical heat flux) was conducted for water boiling two-phase flow in three-pin tight rod bundle. The effects of with and without wire spacers and the pitch to diameter ratio p/d on CHF were investigated under the conditions of mass flux range 250-430 kg/(m2·s), inlet temperature from 70 ℃ to 92 ℃ and the pressure of 0.1 MPa. The CHF was enhanced by wire spacers in comparison with the results of CHF without wire spacers. The CHF was enhanced by reducing thep/dfrom 1.18 to 1.10 under the same flow rate condition, although it did not change appreciably with the change ofp/d under the same mass flux condition.
文摘In order to investigate the coolability of a tight lattice core in BWR (boiling water reactors), an experiment of CHF (critical heat flux) was conducted using a single heater pin flow channel with and without a wire spacer with the mass flux ranged from 200 kg/(m2.s) to 600 kg/(m2·s), the inlet temperature from 50 ℃ to 90 ℃ at the pressure of 0.1 MPa. The results of CHF values were compared between two different types of heater pin with and without the wire spacer. The heat removability of flow channel was improved by the wire spacer in comparison with the heater pin flow channel without the wire spacer. The CHF value was higher in the heater pin channel with the wire spacer than in that without the wire spacer.