Rapid drawdown is a critical design condition for the upstream or riverside slope of earth dams and levees. A new total stress rapid drawdown method based on finite element analysis is used to analyze the rapid drawdo...Rapid drawdown is a critical design condition for the upstream or riverside slope of earth dams and levees. A new total stress rapid drawdown method based on finite element analysis is used to analyze the rapid drawdown failure that occurred at Pilarcitos Dam in 1969. Effective consolidation stresses in the slope prior to drawdown are determined using linear elastic finite element analysis. Undrained strengths from isotropically consolidated undrained (ICU) triaxial compression tests are related directly to the calculated consolidation stresses and assigned to the elements in the model by interpolation. Two different interpretations of the undrained strength envelope are examined. Strength reduction finite element analyses are used to evaluate stability of the dam. Back analysis suggests that undrained strengths from ICU tests must be reduced by 30% for use with this rapid drawdown method. The failure mechanism predicted for Pilarcitos Dam is sensitive to the relationship between undrained strength and consolidation stress.展开更多
文摘Rapid drawdown is a critical design condition for the upstream or riverside slope of earth dams and levees. A new total stress rapid drawdown method based on finite element analysis is used to analyze the rapid drawdown failure that occurred at Pilarcitos Dam in 1969. Effective consolidation stresses in the slope prior to drawdown are determined using linear elastic finite element analysis. Undrained strengths from isotropically consolidated undrained (ICU) triaxial compression tests are related directly to the calculated consolidation stresses and assigned to the elements in the model by interpolation. Two different interpretations of the undrained strength envelope are examined. Strength reduction finite element analyses are used to evaluate stability of the dam. Back analysis suggests that undrained strengths from ICU tests must be reduced by 30% for use with this rapid drawdown method. The failure mechanism predicted for Pilarcitos Dam is sensitive to the relationship between undrained strength and consolidation stress.