期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Performance of Large Area Thin-Film CdTe Detector in Diagnostic X-Ray Imaging
1
作者 diana shvydka , Xiance Jin E. Ishmael Parsai 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2013年第3期98-109,共12页
Significant advancement in thin-film cadmium telluride (CdTe) deposition techniques in recent years has made this material attractive for the development of low-cost large area detector. Here we evaluate the intrinsic... Significant advancement in thin-film cadmium telluride (CdTe) deposition techniques in recent years has made this material attractive for the development of low-cost large area detector. Here we evaluate the intrinsic performance of the detector for a range of energies relevant to diagnostic imaging applications, such as fluoroscopy. The input x-ray spectra for a set of tube potentials ranging from 70 to 140 kVp were computed with the tungsten anode spectral model using interpolating polynomials (TASMIP) based on the measured output of our diagnostic x-ray simulator. Frequency-dependent detector performance analysis was conducted through Monte Carlo simulations of energy deposition within the detector. Intrinsic modulation transfer functions (MTF), noise power spectra (NPS), and detective quantum efficiencies (DQE) were computed for a set of CdTe detectors of varying thickness, from 100 to 1000 μm. MTF behavior at higher frequencies was affected by thickness and input energy, NPS increased with film thickness and energy, and the resultant DQE(f) decreased with increasing the input energy, but increased with the thickness of the detector. We found that the optimal thickness of CdTe under diagnostic x-ray beam is in the range of 300 to 600 μm. Physical properties of CdTe, such as the high atomic number and density, used in direct detection configuration, together with the recently established thin-film manufacturing techniques makes this technology a promising photoconductor for large area diagnostic flat panel imaging. 展开更多
关键词 MONTE Carlo CDTE DETECTOR PHOTOVOLTAIC THIN Film TASMIP DQE X-Ray Imaging
下载PDF
Comparative Study of Experimental Enhancement in Free Radical Generation against Monte Carlo Modeled Enhancement in Radiation Dose Deposition Due to the Presence of High Z Materials during Irradiation of Aqueous Media
2
作者 Nava Paudel diana shvydka E. Ishmael Parsai 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第4期300-307,共8页
Purpose: To investigate conflicting results demonstrating higher cell-kill by irradiated high atomic number (Z) material, gold (Au) in tumor compared to Monte Carlo (MC) modeled enhancement in radiation dose depositio... Purpose: To investigate conflicting results demonstrating higher cell-kill by irradiated high atomic number (Z) material, gold (Au) in tumor compared to Monte Carlo (MC) modeled enhancement in radiation dose deposition, and to compare the difference between radiosensitizing effects of gold and platinum. Methods and Materials: Since a majority of cell kill due to radiation is mediated by free radicals, evaluation of radicals generated from radiolysis of an aqueous medium can provide some insight into cell-kill. Here, free radicals generated due to the radiolysis of water by a clinical Iridium-192 (Ir-192) brachytherapy source in the presence and absence of thin and pure gold or platinum wires were quantified with electron paramagnetic/spin resonance (EPR/ESR) spectrometry and enhancements in free radical generation due to the presence of the wires during radiolysis were calculated. Those enhancements were compared against MC modeled enhancement in radiation dose deposition obtained from the geometry replicating the experimental setup. Results: Enhancements in free radical generation due to 100 and 127 μm diameter gold wires, and 127 μm diameter platinum wire were more than two times higher than the corresponding MC modeled enhancements in radiation dose deposition. Enhancement in hydroxyl free radical (OH?) generation due to thicker wires of gold and platinum were close to the enhancements in radiation dose deposition. The effects were similar for gold and platinum wires of equal diameter. Conclusions: Higher enhancement in radical generation compared to MC modeled enhancement in radiation dose deposition due to micron-size pure gold and platinum wires demonstrates that the surfaces of high Z materials in aqueous media become a secondary source of radicals under radiation field. High surface-to-volume ratio of nanoparticles can make this effect more pronounced, leading to higher cell kill than the predictions based on pure dose enhancement. 展开更多
关键词 HYDROXYL RADICAL EPR/ESR SPECTROMETRY Monte Carlo Ir-192 Nanoparticles
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部