期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Obstacle recognition using a haptic device
1
作者 Kyungwook Noh donghyuk lee +2 位作者 Sunkyun Kang Jaewon An Jangmyung lee 《Journal of Measurement Science and Instrumentation》 CAS 2013年第4期376-380,共5页
A haptic device is proposed which gives the user feedback information on their location and orientation of the obstacle through the mobile robot that detects the obstacle in an environment where the user cannot see.Mo... A haptic device is proposed which gives the user feedback information on their location and orientation of the obstacle through the mobile robot that detects the obstacle in an environment where the user cannot see.Mobile robot recognizes the exact position of the obstacle through configuring the nested ultrasonic sensor and giving feedback information to the haptic device.The haptic device consisting of five vibration motors can realize the haptic through the vibration of user's finger using the position information of the obstacle received feedback.In addition,it has high accuracy to recognize the surrounding environment and realizes the various situations with the fuzzy controller and the nested ultrasonic sensors. 展开更多
关键词 haptic device TELEOPERATION haptic feedback mobile robot obstacle recognitionDocument code:AArticle ID:1674-8042(2013)04-0376-05
下载PDF
Heating performance of a ground source heat pump system installed in a school building 被引量:5
2
作者 Jaedo SONG Kwangho lee +5 位作者 Youngman JEONG Seongir CHEONG Jaekeun lee Yujin HWANG Yeongho lee donghyuk lee 《Science China(Technological Sciences)》 SCIE EI CAS 2010年第1期80-84,共5页
The heating performance of a water-to-refrigerant type ground source heat pump system is represented in this paper under the actual working conditions of the GSHP(ground source heat pump) system during the winter seas... The heating performance of a water-to-refrigerant type ground source heat pump system is represented in this paper under the actual working conditions of the GSHP(ground source heat pump) system during the winter season of 2008.Ten heat pump equipments with the capacity of 10 HP each and a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth were constructed.We investigated a variety of working conditions,including the outdoor temperature,the ground temperature,and the water temperature of inlet and outlet of the ground heat exchanger in order to examine the heating performance of the GSHP system.Subsequently,the heating capacity and the input power were investigated to determine the heating performance of the GSHP system.The average heating coefficient of performance(COP) of the heat pump was noted to be 5.1 at partial load of 47%,while the overall system COP was found to be 4.2.Also,performance of the GSHP system was compared with that of air source heat pump. 展开更多
关键词 ground SOURCE HEAT pump(GSHP) water-to-refrigerant heating PERFORMANCE coefficient of performance(COP) air SOURCE HEAT pump(ASHP)
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部