AIMTo assess the repeatability of measuring optic nerve head (ONH) parameters using the Cirrus optical coherence tomography (OCT), as well as to assess the effect of head tilt on these measurements.METHODSThirty healt...AIMTo assess the repeatability of measuring optic nerve head (ONH) parameters using the Cirrus optical coherence tomography (OCT), as well as to assess the effect of head tilt on these measurements.METHODSThirty healthy participants with no evidence of glaucoma were recruited for the study. Visual acuity, intraocular pressure, standard automated perimetry and ocular examination were performed for each participant. One eye was then randomly selected and scanned undilated with the Cirrus OCT in 3 positions (neutral, 30° right tilt and 30° left tilt).RESULTSData collected from 29 eyes were used for analysis. One patient was omitted due to poor scan quality. The repeatability of the ONH parameters was analyzed using analysis of variance, coefficient of variation (COV) and intraclass correlation coefficient (ICC). Analysis of variance showed no statistically significant difference between 3 scans in a single position. There was good agreement between measurements (ICC 0.919-0.996, COV 1.94%-5.48%). Even with the presence of head tilt, repeated scans in the 3 positions showed good agreement as well (ICC 0.888-0.996, COV 2.04%-5.39%).CONCLUSIONSerial measurements of ONH parameters using the Cirrus OCT are found to have good repeatability. The ONH parameters with Cirrus OCT also maintain good repeatability despite head tilt.展开更多
AIM: To determine angle closure agreements between gonioscopy and anterior segment optical coherence tomography(AS-OCT), as well as gonioscopy and spectral domain OCT(SD-OCT). A secondary objective was to quantify int...AIM: To determine angle closure agreements between gonioscopy and anterior segment optical coherence tomography(AS-OCT), as well as gonioscopy and spectral domain OCT(SD-OCT). A secondary objective was to quantify inter-observer agreements of AS-OCT and SD-OCT assessments.METHODS: Seventeen consecutive subjects(33 eyes)were recruited from the study hospital’s Glaucoma clinic.Gonioscopy was performed by a glaucomatologist masked to OCT results. OCT images were read independently by 2 other glaucomatologists masked to gonioscopy findings as well as each other’s analyses of OCT images.RESULTS: Totally 84.8% and 45.5% of scleral spurs were visualized in AS-OCT and SD-OCT images respectively(P 【0.01). The agreement for angle closure between AS-OCT and gonioscopy was fair at k =0.31(95% confidence interval, CI: 0.03-0.59) and k =0.35(95%CI: 0.07-0.63) for reader 1 and 2 respectively. The agreement for angle closure between SD-OCT and gonioscopy was fair at k =0.21(95% CI: 0.07-0.49) and slight at k =0.17(95% CI: 0.08-0.42) for reader 1 and 2 respectively. The inter-reader agreement for angle closure in AS-OCT images was moderate at 0.51(95% CI: 0.13-0.88). The inter-reader agreement for angle closure in SD-OCT images was slight at 0.18(95% CI: 0.08-0.45).CONCLUSION: Significant proportion of scleral spurs were not visualised with SD-OCT imaging resulting in weaker inter-reader agreements. Identifying other angle landmarks in SD-OCT images will allow more consistent angle closure assessments. Gonioscopy and OCT imaging do not always agree in angle closure assessments but have their own advantages, and should be used together and not exclusively.展开更多
文摘AIMTo assess the repeatability of measuring optic nerve head (ONH) parameters using the Cirrus optical coherence tomography (OCT), as well as to assess the effect of head tilt on these measurements.METHODSThirty healthy participants with no evidence of glaucoma were recruited for the study. Visual acuity, intraocular pressure, standard automated perimetry and ocular examination were performed for each participant. One eye was then randomly selected and scanned undilated with the Cirrus OCT in 3 positions (neutral, 30° right tilt and 30° left tilt).RESULTSData collected from 29 eyes were used for analysis. One patient was omitted due to poor scan quality. The repeatability of the ONH parameters was analyzed using analysis of variance, coefficient of variation (COV) and intraclass correlation coefficient (ICC). Analysis of variance showed no statistically significant difference between 3 scans in a single position. There was good agreement between measurements (ICC 0.919-0.996, COV 1.94%-5.48%). Even with the presence of head tilt, repeated scans in the 3 positions showed good agreement as well (ICC 0.888-0.996, COV 2.04%-5.39%).CONCLUSIONSerial measurements of ONH parameters using the Cirrus OCT are found to have good repeatability. The ONH parameters with Cirrus OCT also maintain good repeatability despite head tilt.
文摘AIM: To determine angle closure agreements between gonioscopy and anterior segment optical coherence tomography(AS-OCT), as well as gonioscopy and spectral domain OCT(SD-OCT). A secondary objective was to quantify inter-observer agreements of AS-OCT and SD-OCT assessments.METHODS: Seventeen consecutive subjects(33 eyes)were recruited from the study hospital’s Glaucoma clinic.Gonioscopy was performed by a glaucomatologist masked to OCT results. OCT images were read independently by 2 other glaucomatologists masked to gonioscopy findings as well as each other’s analyses of OCT images.RESULTS: Totally 84.8% and 45.5% of scleral spurs were visualized in AS-OCT and SD-OCT images respectively(P 【0.01). The agreement for angle closure between AS-OCT and gonioscopy was fair at k =0.31(95% confidence interval, CI: 0.03-0.59) and k =0.35(95%CI: 0.07-0.63) for reader 1 and 2 respectively. The agreement for angle closure between SD-OCT and gonioscopy was fair at k =0.21(95% CI: 0.07-0.49) and slight at k =0.17(95% CI: 0.08-0.42) for reader 1 and 2 respectively. The inter-reader agreement for angle closure in AS-OCT images was moderate at 0.51(95% CI: 0.13-0.88). The inter-reader agreement for angle closure in SD-OCT images was slight at 0.18(95% CI: 0.08-0.45).CONCLUSION: Significant proportion of scleral spurs were not visualised with SD-OCT imaging resulting in weaker inter-reader agreements. Identifying other angle landmarks in SD-OCT images will allow more consistent angle closure assessments. Gonioscopy and OCT imaging do not always agree in angle closure assessments but have their own advantages, and should be used together and not exclusively.