期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Measuring Salinity within Shallow Piezometers:Comparison of Two Field Methods
1
作者 enrico balugani Marco Antonellini 《Journal of Water Resource and Protection》 2010年第3期251-258,共8页
The objective of this study is to understand the validity of salinity vertical profiles collected from shallow piezometers that are not previously flushed. This study shows that salinity data collected from boreholes ... The objective of this study is to understand the validity of salinity vertical profiles collected from shallow piezometers that are not previously flushed. This study shows that salinity data collected from boreholes are only an average value along the entire screened section of the piezometer. In order to collect data that is rep-resentative for the salinity of the adjacent aquifer, a new monitoring strategy has been developed. This strat-egy includes measurement of the salinity at the top of the watertable in an auger hole which is a shallow boreholes made with an handheld drill. This should be combined with measurements in piezometers that are first flushed to take out stagnant water. From the piezometers on can measure the average salinity of the screened part and the salinity at the bottom of the aquifer. By using this monitoring strategy it is also possi-ble to define where the piezometers screens are located if this is not known beforehand. 展开更多
关键词 COASTAL AQUIFER Salt-Water INTRUSION Piezometers Monitoring