期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas 被引量:7
1
作者 Gabor Nemeth eszter szalai +3 位作者 Ziad Hassan Agnes Lipecz Zsuzsa Flasko Laszlo Modis 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第2期217-222,共6页
AIM: To analyze the correlations between ocular biomechanical and biometric data of the eye,measured by Scheimpflug-based devices on healthy subjects.METHODS: Three consecutive measurements were carried out using th... AIM: To analyze the correlations between ocular biomechanical and biometric data of the eye,measured by Scheimpflug-based devices on healthy subjects.METHODS: Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology(Cor Vis ST) device on healthy eyes and the 10 device-specific parameters were recorded.Pentacam HR-derived parameters(corneal curvature radii on the anterior and posterior surfaces;apical pachymetry;corneal volume;corneal aberration data;depth,volume and angle of the anterior chamber) and axial length(AL) from IOLMaster were correlated with the 10 specific CorV is ST parameters.RESULTS: Measurements were conducted in 43 eyes of 43 volunteers(age 61.24±15.72y).The 10 specific Cor Vis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface,pachymetric data,root mean square(RMS) data of lower-order aberrations,and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea.Anterior chamber depth showed a significant relationship,but there were no significant correlations between corneal volume,anterior chamber volume,mean chamber angle or AL and the 10 specific CorV is ST parameters.CONCLUSION: Cor Vis ST-generated parameters are influenced by corneal curvature radii,some corneal RMS data,but corneal volume,anterior chamber volume,chamber angle and AL have no correlation with the biomechan-ical parameters.The parameters measured by CorV is ST seem to refer mostly to corneal properties of the eye. 展开更多
关键词 anterior segment parameters biomechan-ics corneal visualization Scheimpflug technology OcularResponse Analyzer
下载PDF
Scheimpflug imaged corneal changes on anterior and posterior surfaces after collagen cross-linking 被引量:1
2
作者 Ziad Hassan Laszlo Modis +2 位作者 eszter szalai Andras Berta Gabor Nemeth 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期313-316,共4页
AIM:To compare the anterior and posterior corneal parameters before and after collagen cross-linking therapy for keratoconus.METHODS:Collagen cross-linking was performed in31 eyes of 31 keratoconus patients(mean age 3... AIM:To compare the anterior and posterior corneal parameters before and after collagen cross-linking therapy for keratoconus.METHODS:Collagen cross-linking was performed in31 eyes of 31 keratoconus patients(mean age 30.6±8.9y).Prior to treatment and an average 7mo after therapy,Scheimpflug analysis was performed using Pentacam HR.In addition to corneal thickness assessments,corneal radius,elevation,and aberrometric measurements were performed both on anterior and posterior corneal surfaces.Data obtained before and after surgery were statistically analyzed.RESULTS:In terms of horizontal and vertical corneal radius,and central corneal thickness no deviations were observed an average 7mo after operation.Corneal higher order aberration showed no difference neither on anterior nor on posterior corneal surfaces.During follow-up period,no significant deviation was detected regarding elevation values obtained by measurement in mm units between the 3.0-8.0 mm-zones.CONCLUSION:Corneal stabilization could be observed in terms of anterior and posterior corneal surfaces,elevation and higher order aberration values 7mo after collagen cross-linking therapy for keratoconus. 展开更多
关键词 corneal back surface higher order aberration elevation collagen cross-linking high resolution Pentacam
下载PDF
Ocular biomechanical measurements on post- keratoplasty corneas using a Scheimpflug-based noncontact device 被引量:1
3
作者 Laszlo Modis Jr. Ziad Hassan +3 位作者 eszter szalai Zsuzsanna Flasko Andras Berta Gabor Nemeth 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第2期235-238,共4页
AIM: To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (lOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. ... AIM: To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (lOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas. METHODS: Measurements were conducted on 46 eyes of 46 healthy patients without any corneal pathology (age: 53.83 ±20.8y) and 30 eyes of 28 patients after penetrating keratoplasty (age: 49.43 ±21.34y). Ten biomechanical parameters, the CCT and lOP were recorded by corneal visualization Scheimpflug technology (CorVis ST) using high-speed Scheimpflug imaging. Keratometry values were also recorded using Pentacam HR system. Scheimpflug measurements were performed after 43.41± 40.17mo (range: 11-128mo) after the keratoplasty and after 7.64±2.34mo (range: 5-14mo) of suture removal. RESULTS: Regarding the device-specific biomechanical parameters, the highest concavity time and radius values showed a significant decrease between these two groups (P=0.01 and P 〈0.001). None of other biomechanical parameters disclosed a significant difference. The CCT showed a significant difference between post keratoplasty eyes as compared to normal subjects (P= 0.003) using the CorVis ST device. The lOP was within the normal range in both groups (P=0.84). There were no significant relationships between the keratometric data, the size of the donor and recipient, age of the donor and recipient and biomechanical properties obtained by CorVis ST. CONCLUSION: The ocular biomechanics remain stable after penetrating keratoplasty according to the CorVis ST measurements. Only two from the ten device-specific parameters have importance in the follow-up period after penetrating keratoplasty. 展开更多
关键词 corneal visualization Scheimpflugtechnology ocular biomechanics penetrating keratoplasty
下载PDF
Scanning-slit topography in patients with keratoconus
4
作者 László Módis Jr. Gábor Németh +2 位作者 eszter szalai Zsuzsa Flaskó Berthold Seitz 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第11期1686-1692,共7页
AIM: To evaluate the anterior and posterior corneal surfaces using scanning-slit topography and to determine the diagnostic ability of the measured corneal parameters in keratoconus.METHODS: Orbscan II measurements ... AIM: To evaluate the anterior and posterior corneal surfaces using scanning-slit topography and to determine the diagnostic ability of the measured corneal parameters in keratoconus.METHODS: Orbscan II measurements were taken in 39 keratoconic corneas previously diagnosed by corneal topography and in 39 healthy eyes. The central minimum, maximum, and astigmatic simulated keratometry(K) and anterior axial power values were determined. Spherical and cylindrical mean power diopters were obtained at the central and at the steepest point of the cornea both on anterior and on posterior mean power maps. Pachymetry evaluations were taken at the center and paracentrally in the 3 mm zone from the center at a location of every 45 degrees. Receiver operating characteristic(ROC) analysis was used to determine the best cut-off values and to evaluate the utility of the measured parameters in identifying patients with keratoconus.RESULTS: The minimum, maximum and astigmatic simulated K readings were 44.80±3.06 D, 47.17±3.67 D and 2.42±1.84 D respectively in keratoconus patients and these values differed significantly(P〈0.0001 for all comparisons) from healthy subjects. For all pachymetry measurements and for anterior and posterior mean power values significant differences were found between the two groups. Moreover, anterior central cylindrical power had the best discrimination ability(area under the ROC curve=0.948).CONCLUSION: The results suggest that scanning-slit topography and pachymetry are accurate methods both for keratoconus screening and for confirmation of the diagnosis. 展开更多
关键词 keratoconus Orbscan topography pachymetry
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部