Wireless capsule endoscopy in the investigation of patients with chronic renal failure and obscure gastrointestinal bleeding (preliminary data) 被引量:8
1
作者 Stephanos Karagiannis Spyros Goulas +5 位作者 Georgios Kosmadakis Petros Galanis Dimitrios Arvanitis John Boletis evangelos georgiou Christos Mavrogiannis 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第32期5182-5185,共4页
瞄准:在小肠(SB ) 的察觉调查无线的囊内视镜检查法(WCE ) 的角色在有长期的肾衰竭(CRF ) 并且阴暗流血的病人的病理。方法:有阴暗流血的连续 CRF 病人有希望地被学习。有正常肾的功能并且阴暗流血的病人,与 WCE 在一样的时期期间调... 瞄准:在小肠(SB ) 的察觉调查无线的囊内视镜检查法(WCE ) 的角色在有长期的肾衰竭(CRF ) 并且阴暗流血的病人的病理。方法:有阴暗流血的连续 CRF 病人有希望地被学习。有正常肾的功能并且阴暗流血的病人,与 WCE 在一样的时期期间调查了,被用于结果的解释。结果:十七个 CRF 病人(11 公开, 6 玄术流血) 并且 51 个病人(33 公开, 18 玄术流血) 与正常,肾的功能在这研究被注册。积极 SB 调查结果在 70.6% CRF 病人被检测(P 【 0.05 ) 。SB angiodysplasia 在 47% CRF 病人被识别。Univariate 逻辑回归为 angiodysplasia 作为一个重要预兆的因素揭示了 CRF (P 【 0.05 ) 。治疗学的措施与积极调查结果在 66% 病人被承担。结论:根据我们的初步的结果, SB angiodysplasia 与阴暗流血在 CRF 病人之中在增加的流行被发现。WCE 在胃肠的病理的诊断并且在计划适当治疗学的干预是有用的并且因此,应该在这组病人的病情的检查被包括。 展开更多
关键词 内窥镜 慢性肾疾病 肾功能 胃疾病 肠疾病
下载PDF
Performance comparison between three intraoral image receptors of different technology at a variety of tube potential, tube current and exposure time settings using a stepwedge phantom
2
作者 Elli Katsoni Ioannis A. Tsalafoutas +3 位作者 Panagiotis Gritzalis Evripidis Stefanou evangelos georgiou Emmanuel Yakoumakis 《Health》 2011年第1期56-65,共10页
Purpose: To comparatively evaluate the per-formance of three intraoral image receptors of different technology when exposed to different X-ray beam spectra, dose and dose rate levels using a stepwedge phantom. Materia... Purpose: To comparatively evaluate the per-formance of three intraoral image receptors of different technology when exposed to different X-ray beam spectra, dose and dose rate levels using a stepwedge phantom. Materials and methods: The intraoral radiographic receptors evaluated were: the Kodak Insight F speed class film, the Kodak RVG 6000, and the Duerr Vis-tascan Combi PSP system. A dental quality control phantom made of Plexiglas, containing an aluminium stepwedge with 12 steps and 7 holes drilled in each step was radiographed using a dental X-ray unit offering a wide range of tube potential, tube current and exposure time settings. The visibility of the holes in the images produced with each one of the three receptors was assessed by three independent observers. For each image the total image quality score (TS) was derived from the summation of the number of visible holes in each step. The numbers of perceptible holes in each experimental condition (TSs) were statistically analyzed through use of analysis of variance. Intraobserver and interobserver agree-ment was also measured. Results: Vistascan ex-hibited the most extended useful exposure range, followed by RVG 6000 and Insight. RVG 6000 exhibited the largest TS values in all tube potential settings except 70 kV where the Vistascan performed better. Insight performed better than Vistascan only at 60 and 63 kV. Vistascan performed better at 66 and 70 kV, Insight at 60 and 66 kV, whereas RVG performed equally well at all tube potential settings, except than at 52 and 70 kV. For the Insight the largest TS values were obtained with the smallest ESAK values whereas with the Vistascan the largest TS were obtained with ESAK values that where the largest observed. Conclusions: The performance of all receptors tested was greatly dependent on the exposure parameters and mainly on the kV settings. Overall, the RVG 6000 offered the best image quality at doses somewhere in between those required by the Insight and the Vistascan. 展开更多
关键词 RADIOGRAPHY Dental Digital DOSAGE
下载PDF
Exploring the useful exposure range limits of three intraoral image receptors for various tube potential, tube current and exposure time settings
3
作者 Elli Katsoni Ioannis A. Tsalafoutas +3 位作者 Panagiotis Gritzalis Evripides Stefanou evangelos georgiou Emmanouel Yakoumakis 《Health》 2011年第5期292-299,共8页
Objectives: To determine the useful exposure range limits of three intraoral image receptors of different technology when exposed to different X-ray beam spectra, dose and dose rate levels. Study Design: A dental X-ra... Objectives: To determine the useful exposure range limits of three intraoral image receptors of different technology when exposed to different X-ray beam spectra, dose and dose rate levels. Study Design: A dental X-ray unit offering a wide range of tube potential, tube current and exposure time settings was used to expose a dental quality control phantom. The receptors that were used to capture the radiographic images of the phantom were: the Kodak Insight, the Kodak RVG-6000 and the Duerr Vistascan system. The images that were produced over a wide range of exposure factor settings were evaluated in terms of diagnostic quality by three experienced radiologists. Results: The number of images with acceptable diagnostic quality was in total 1257;310 with Insight, 331 with RVG 6000 and 616 with Vistascan. At 60 kV, diagnosable images were produced with doses ranging from 0.44-1.56 mGy for the Insight film 0.44-2.82 mGy for the RVG 6000 and 0.22-4.93 mGy for the Vistascan system. At 70 kV, the respective ranges were 0.39-1.28 mGy for the Insight film 0.31-2.55 mGy for the RVG6000 and 0.30-3.46 mGy for the Vistascan system. Conclusions: The Vistascan exhibited the widest useful exposure range and required the least exposure to produce a diagnosable image at almost all tube potential settings. The RVG 6000 exhibited a slightly wider useful exposure range than the Insight film, with almost the same dose requirements especially in higher Kv settings. 展开更多
关键词 RADIOGRAPHY Dental Digital DOSAGE
下载PDF