The 5.8 S ribosomal DNA sequences (5.8S rDNA) and their flanking regions, internal transcribed spacer 1 and spacer 2 (ITS1 and ITS2) of three new isolates in genus Alexandrium (Alexandrium sp. qd1, Alexandrium sp. qd2...The 5.8 S ribosomal DNA sequences (5.8S rDNA) and their flanking regions, internal transcribed spacer 1 and spacer 2 (ITS1 and ITS2) of three new isolates in genus Alexandrium (Alexandrium sp. qd1, Alexandrium sp. qd2, Alexandrium sp. gz) from China were amplified, sequenced, and subjected to phylogenetic analysis. Alexandrium sp. gz and Alexandrium sp. qd1 were grouped with high bootstrap values with four strains/species, i.e., A. catenella South Korea strain, A. catenella Japan strain, and two from China, Alexandrium sp. AC03 and Alexandrium sp. AN01 being proposed to be A. catenalla in a previous study. Then Alexandrium sp. gz and Alexandrium sp. qd1 were identified as Alexandrium catenella. As A. catenella was isolated from Qingdao and Guangzhou sea areas, it supposedly distributed at least in these two areas and was genetically different. Alexandrium sp. qd2 differed greatly from species in Alexandrium. It clustered with Symbiodinium californium, Symbiodinium sp. G15 and Gymnodinium sp. Zhao 01 with 100% bootstrap value; so Alexandrium sp. qd2 affiliates to genus Symbiodinium, and is probably a free-living Symbiodinium species.展开更多
Diabetic nephropathy is one of the most common causes of end-stage renal disease worldwide and is associated with increased mortality in patients with type 1 and type 2 diabetes.Autophagy is a highly conserved"au...Diabetic nephropathy is one of the most common causes of end-stage renal disease worldwide and is associated with increased mortality in patients with type 1 and type 2 diabetes.Autophagy is a highly conserved"autophagy"pathway and is an important mechanism for maintaining glomerular and tubular homeostasis.Emerging evidence suggests that targeted autophagy pathway activation and restoration of autophagy activity may have renal protection.Glomerular endothelial cells are an important key factor in the development of diabetic nephropathy.Endothelial dysfunction is involved in the development of diabetic and non-diabetic glomerular injury and renal fibrosis.Evidence of glomerular endothelial dysfunction in the late stages of diabetic nephropathy,such as thrombotic microangiopathy,including impairment of glomerular capillary microaneurysms and glomerular membrane lysis autophagy,is related to the pathogenesis of diabetic nephropathy.Here,we mainly introduced the research progress of the effects of glomerular endothelial cell autophagy on diabetic nephropathy.展开更多
Objective The dialysate membrane can be classified into acetate membrane and synthetic membrane,while the latter can be further divided into polysulfone,polyacrylonitrile,etc.Polyethersulfone membrane is high molecula...Objective The dialysate membrane can be classified into acetate membrane and synthetic membrane,while the latter can be further divided into polysulfone,polyacrylonitrile,etc.Polyethersulfone membrane is high molecular membrane material with excellent biocompatibility,stable mechanical properties,high temperature and pressure resistance,and good cleaning performance,which has been applied for more than 10 years.This trial is to assess the safety and efficacy of hollow polysulfone membrane fiber dialyzer with pattern number Enttex^(TM)-16LF(E60)for hemodialysis in patients with acute or chronic renal failure due to multiple factors.Methods Totally 76 patients receiving maintenance hemodialysis were included in a two-site,random,open label,two-stage,positive crossover and non inferiority validation study.The clinical efficacy and safety of the test device were observed,which was a hollow fiber dialyzer produced by Guangzhou Enttex Medical Products Co.,Ltd.,with polyethersulfone membrane imported from Germany.It was a low flux dialyzer with the pattern number of EnttexTM-16LF(E60).Inclusion criteria:①patients with acute or chronic renal failure due to various reasons who needed hemodialysis;②18 to 80 years old,gender unlimited;③patients who received stable dialysis for more than 3 months,regular hemodialysis 3 times a week,4 h at each time,blood flow rate of 200~350ml/min;④using bicarbonate dialysate at a flow rate of 500ml/min;⑤patients with arteriovenous fistula or who received artificial blood vessel puncture dialysis;received anticoagulation by heparin or low molecular weight heparin.Exclusion criteria:①patients needing heparin free dialysis for severe anemia,tumor and active bleeding;②patients with severe cardiac(gradeⅢcardiac function),hepatic(severe hepatitis and cirrhosis)and pulmonary diseases(severe respiratory failure).Results Comparison of parameters,including the changes of Kt/V,general creatinine and urea clearance rates and URR(urea reduction rate)shows no statistical significance in differences between the two devices,indicating that the test and control devices can equally and effectively eliminate toxins including creatinine and urea,etc.PPP and MITTP results are consistent.Comparison of ultrafiltration rates between two groups of patients shows no statistical difference.PPP and MITTP results are consistent,indicating that both the test device and control device can effectively eliminate water.In MITTP,electrolytes including K^+,Na^+,Cl^-,Ca^2+,HCO3^-,etc.show no statistical significance in difference between the test and control devices before and after dialysis(P>0.05).After treating by using test and control devices,body weight,serum potassium and phos-phorus all significantly decrease(P<0.001);serum Ca^2+,PO2,PCO2and HCO3^-all significantly increase(P<0.001).These results indicate that both the test and control devices can effectively eliminate serum potassium and phosphorus,and eliminate excess water in body,maintain the balance between liquid and electrolytes in patients.PPP and MITTP results are consistent.Conclusion This clinical trial confirms that hollow polyethersulfone membrane fiber dialyzer can be safely and effectively used in hemodialysis therapy.展开更多
Vitamin C is an essential vitamin for people,but it possibly linked to an increased risk of kidney stones.This view is controversial.The purpose of this assess was to illuminate the relationship between vitamin C inta...Vitamin C is an essential vitamin for people,but it possibly linked to an increased risk of kidney stones.This view is controversial.The purpose of this assess was to illuminate the relationship between vitamin C intake and kidney stones.This paper reviewed relevant articles in the past 40 years from pubmed,analyzed the correlation between vitamin C intake and kidney stones,and pointed out the problems in the research process,which is of great reference significance.展开更多
文摘The 5.8 S ribosomal DNA sequences (5.8S rDNA) and their flanking regions, internal transcribed spacer 1 and spacer 2 (ITS1 and ITS2) of three new isolates in genus Alexandrium (Alexandrium sp. qd1, Alexandrium sp. qd2, Alexandrium sp. gz) from China were amplified, sequenced, and subjected to phylogenetic analysis. Alexandrium sp. gz and Alexandrium sp. qd1 were grouped with high bootstrap values with four strains/species, i.e., A. catenella South Korea strain, A. catenella Japan strain, and two from China, Alexandrium sp. AC03 and Alexandrium sp. AN01 being proposed to be A. catenalla in a previous study. Then Alexandrium sp. gz and Alexandrium sp. qd1 were identified as Alexandrium catenella. As A. catenella was isolated from Qingdao and Guangzhou sea areas, it supposedly distributed at least in these two areas and was genetically different. Alexandrium sp. qd2 differed greatly from species in Alexandrium. It clustered with Symbiodinium californium, Symbiodinium sp. G15 and Gymnodinium sp. Zhao 01 with 100% bootstrap value; so Alexandrium sp. qd2 affiliates to genus Symbiodinium, and is probably a free-living Symbiodinium species.
文摘Diabetic nephropathy is one of the most common causes of end-stage renal disease worldwide and is associated with increased mortality in patients with type 1 and type 2 diabetes.Autophagy is a highly conserved"autophagy"pathway and is an important mechanism for maintaining glomerular and tubular homeostasis.Emerging evidence suggests that targeted autophagy pathway activation and restoration of autophagy activity may have renal protection.Glomerular endothelial cells are an important key factor in the development of diabetic nephropathy.Endothelial dysfunction is involved in the development of diabetic and non-diabetic glomerular injury and renal fibrosis.Evidence of glomerular endothelial dysfunction in the late stages of diabetic nephropathy,such as thrombotic microangiopathy,including impairment of glomerular capillary microaneurysms and glomerular membrane lysis autophagy,is related to the pathogenesis of diabetic nephropathy.Here,we mainly introduced the research progress of the effects of glomerular endothelial cell autophagy on diabetic nephropathy.
基金Guangdong Provincial Science and Technology Department Fund Project(507204531040)Guangdong Provincial Science and Technology Plan Fund Project(2013b9040004)
文摘Objective The dialysate membrane can be classified into acetate membrane and synthetic membrane,while the latter can be further divided into polysulfone,polyacrylonitrile,etc.Polyethersulfone membrane is high molecular membrane material with excellent biocompatibility,stable mechanical properties,high temperature and pressure resistance,and good cleaning performance,which has been applied for more than 10 years.This trial is to assess the safety and efficacy of hollow polysulfone membrane fiber dialyzer with pattern number Enttex^(TM)-16LF(E60)for hemodialysis in patients with acute or chronic renal failure due to multiple factors.Methods Totally 76 patients receiving maintenance hemodialysis were included in a two-site,random,open label,two-stage,positive crossover and non inferiority validation study.The clinical efficacy and safety of the test device were observed,which was a hollow fiber dialyzer produced by Guangzhou Enttex Medical Products Co.,Ltd.,with polyethersulfone membrane imported from Germany.It was a low flux dialyzer with the pattern number of EnttexTM-16LF(E60).Inclusion criteria:①patients with acute or chronic renal failure due to various reasons who needed hemodialysis;②18 to 80 years old,gender unlimited;③patients who received stable dialysis for more than 3 months,regular hemodialysis 3 times a week,4 h at each time,blood flow rate of 200~350ml/min;④using bicarbonate dialysate at a flow rate of 500ml/min;⑤patients with arteriovenous fistula or who received artificial blood vessel puncture dialysis;received anticoagulation by heparin or low molecular weight heparin.Exclusion criteria:①patients needing heparin free dialysis for severe anemia,tumor and active bleeding;②patients with severe cardiac(gradeⅢcardiac function),hepatic(severe hepatitis and cirrhosis)and pulmonary diseases(severe respiratory failure).Results Comparison of parameters,including the changes of Kt/V,general creatinine and urea clearance rates and URR(urea reduction rate)shows no statistical significance in differences between the two devices,indicating that the test and control devices can equally and effectively eliminate toxins including creatinine and urea,etc.PPP and MITTP results are consistent.Comparison of ultrafiltration rates between two groups of patients shows no statistical difference.PPP and MITTP results are consistent,indicating that both the test device and control device can effectively eliminate water.In MITTP,electrolytes including K^+,Na^+,Cl^-,Ca^2+,HCO3^-,etc.show no statistical significance in difference between the test and control devices before and after dialysis(P>0.05).After treating by using test and control devices,body weight,serum potassium and phos-phorus all significantly decrease(P<0.001);serum Ca^2+,PO2,PCO2and HCO3^-all significantly increase(P<0.001).These results indicate that both the test and control devices can effectively eliminate serum potassium and phosphorus,and eliminate excess water in body,maintain the balance between liquid and electrolytes in patients.PPP and MITTP results are consistent.Conclusion This clinical trial confirms that hollow polyethersulfone membrane fiber dialyzer can be safely and effectively used in hemodialysis therapy.
基金2019 Dongguan social science and technology development(key)project(201950715002195)Guangdong provincial science and technology department fund project(507204531040)
文摘Vitamin C is an essential vitamin for people,but it possibly linked to an increased risk of kidney stones.This view is controversial.The purpose of this assess was to illuminate the relationship between vitamin C intake and kidney stones.This paper reviewed relevant articles in the past 40 years from pubmed,analyzed the correlation between vitamin C intake and kidney stones,and pointed out the problems in the research process,which is of great reference significance.