The density of Ni-Al alloys in both liquid state and solid-liquid coexistence state was measured with a modified pycnometric method. It was found that the density of NI-Al alloys decreases with increasing temperature ...The density of Ni-Al alloys in both liquid state and solid-liquid coexistence state was measured with a modified pycnometric method. It was found that the density of NI-Al alloys decreases with increasing temperature and Al concentration in the alloys. The molar volume of liquid Ni-Al binary alloys increases with the increase of temperature and Al concentration. The partial molar volume of Al in NI-Al binary alloy was calculated approximately. The molar volume of liquid NI-Al alloy determined in the present work shows a negative deviation from the ideal linear molar volume.展开更多
The density of liquid binary Ni-Mo alloys with molybdenum concentration from 0 to 20% (mass fraction) was measured by a modified sessile drop method. It has been found that the density of the liquid Ni-Mo alloys decre...The density of liquid binary Ni-Mo alloys with molybdenum concentration from 0 to 20% (mass fraction) was measured by a modified sessile drop method. It has been found that the density of the liquid Ni-Mo alloys decreases with increasing temperature, but increases with the increase of molybdenum concentration in the alloys. The molar volume of liquid Ni-Mo binary alloys increases with the increase of temperature and molybdenum concentration. The partial molar volume of molybdenum in Ni-Mo binary alloy has been approximately calculated as [13.18 - 2.65 × 10-3T + (-47.94 + 3.10 × 10-2T) × 10-2XMo] × 10-6m3·mol-1. The molar volume of Ni-Mo alloy determined in the present work shows a negative deviation from the ideal linear mixing molar volume.展开更多
Density of molten Ni and Ni-W alloys was measured in the temperature range of 1773~1873 K with a sessile drop method.The density of molten Ni and Ni-W alloys trends to decrease with increasing temperature. The densit...Density of molten Ni and Ni-W alloys was measured in the temperature range of 1773~1873 K with a sessile drop method.The density of molten Ni and Ni-W alloys trends to decrease with increasing temperature. The density and molar volume of the alloys trend to increase with increasing W concentration in the alloys. The calculation result shows an ideal mixing of Ni-W alloys.展开更多
AIM: To summarize clinical features of probable severe acute respiratory syndrome (SARS) in Beijing.METHODS: Retrospective cases involving 801 patients admitted to hospitals in Beijing between March and June 2003, wit...AIM: To summarize clinical features of probable severe acute respiratory syndrome (SARS) in Beijing.METHODS: Retrospective cases involving 801 patients admitted to hospitals in Beijing between March and June 2003, with a diagnosis of probable SARS, moderate type.The series of clinical manifestation, laboratory and radiograph data obtained from 801 cases were analyzed. RESULTS: One to three days after the onset of SARS, the major clinical symptoms were fever (in 88.14% of patients), fatigue, headache, myalgia, arthralgia (25-36%), etc. The counts of WBC (in 22.56% of patients) lymphocyte (70.25%)and CD3, CD4, CD8 positive T cells (70%) decreased. From 4-7 d, the unspecific symptoms became weak; however, the rates of low respiratory tract symptoms, such as cough (24.18%), sputum production (14.26%), chest distress (21.04%) and shortness of breath (9.23%) increased, so did the abnormal rates on chest radiograph or CT. The low counts of WBC, lymphocyte and CD3, CD4, CD8 positiveT cells touched bottom. From 8 to 16 d, the patients presented progressive cough (29.96%), sputum production (13.09%), chest distress (29.96%) and shortness of breath (35.34%). All patients had infiltrates on chest radiograph or CT, some even with multi-infiltrates. Two weeks later, patients' respiratory symptoms started to alleviate, the infiltrates on the lung began to absorb gradually, the counts of WBC, lymphocyte and CD3, CD4, CD8 positive T cells were restored to normality.CONCLUSION: The data reported here provide evidence that the course of SARS could be divided into four stages, namely the initial stage, progressive stage, fastigium and convalescent stage.展开更多
Surface tension of molten Ni and Ni-Co (5 and 10 mass fraction) alloys was measured at the temperature range of 1773~1873 K using an improved sessile drop method with an alumina substrate in an Ar+3%H2 atmosphere. T...Surface tension of molten Ni and Ni-Co (5 and 10 mass fraction) alloys was measured at the temperature range of 1773~1873 K using an improved sessile drop method with an alumina substrate in an Ar+3%H2 atmosphere. The error of the data obtained was analyzed. The surface tension of molten Ni and Ni-Co (5 and 10 mass fraction) alloys decreases with increasing temperature. The influence of Co on the surface tension of Ni-Co alloys is little in the studied Co concentration range.展开更多
文摘The density of Ni-Al alloys in both liquid state and solid-liquid coexistence state was measured with a modified pycnometric method. It was found that the density of NI-Al alloys decreases with increasing temperature and Al concentration in the alloys. The molar volume of liquid Ni-Al binary alloys increases with the increase of temperature and Al concentration. The partial molar volume of Al in NI-Al binary alloy was calculated approximately. The molar volume of liquid NI-Al alloy determined in the present work shows a negative deviation from the ideal linear molar volume.
文摘The density of liquid binary Ni-Mo alloys with molybdenum concentration from 0 to 20% (mass fraction) was measured by a modified sessile drop method. It has been found that the density of the liquid Ni-Mo alloys decreases with increasing temperature, but increases with the increase of molybdenum concentration in the alloys. The molar volume of liquid Ni-Mo binary alloys increases with the increase of temperature and molybdenum concentration. The partial molar volume of molybdenum in Ni-Mo binary alloy has been approximately calculated as [13.18 - 2.65 × 10-3T + (-47.94 + 3.10 × 10-2T) × 10-2XMo] × 10-6m3·mol-1. The molar volume of Ni-Mo alloy determined in the present work shows a negative deviation from the ideal linear mixing molar volume.
文摘Density of molten Ni and Ni-W alloys was measured in the temperature range of 1773~1873 K with a sessile drop method.The density of molten Ni and Ni-W alloys trends to decrease with increasing temperature. The density and molar volume of the alloys trend to increase with increasing W concentration in the alloys. The calculation result shows an ideal mixing of Ni-W alloys.
基金Supported by the National High Technology Research and Development Program of China (863 Program), No. 2003AA208107 Correspondence to: Xiao-Yuan Xu
文摘AIM: To summarize clinical features of probable severe acute respiratory syndrome (SARS) in Beijing.METHODS: Retrospective cases involving 801 patients admitted to hospitals in Beijing between March and June 2003, with a diagnosis of probable SARS, moderate type.The series of clinical manifestation, laboratory and radiograph data obtained from 801 cases were analyzed. RESULTS: One to three days after the onset of SARS, the major clinical symptoms were fever (in 88.14% of patients), fatigue, headache, myalgia, arthralgia (25-36%), etc. The counts of WBC (in 22.56% of patients) lymphocyte (70.25%)and CD3, CD4, CD8 positive T cells (70%) decreased. From 4-7 d, the unspecific symptoms became weak; however, the rates of low respiratory tract symptoms, such as cough (24.18%), sputum production (14.26%), chest distress (21.04%) and shortness of breath (9.23%) increased, so did the abnormal rates on chest radiograph or CT. The low counts of WBC, lymphocyte and CD3, CD4, CD8 positiveT cells touched bottom. From 8 to 16 d, the patients presented progressive cough (29.96%), sputum production (13.09%), chest distress (29.96%) and shortness of breath (35.34%). All patients had infiltrates on chest radiograph or CT, some even with multi-infiltrates. Two weeks later, patients' respiratory symptoms started to alleviate, the infiltrates on the lung began to absorb gradually, the counts of WBC, lymphocyte and CD3, CD4, CD8 positive T cells were restored to normality.CONCLUSION: The data reported here provide evidence that the course of SARS could be divided into four stages, namely the initial stage, progressive stage, fastigium and convalescent stage.
文摘Surface tension of molten Ni and Ni-Co (5 and 10 mass fraction) alloys was measured at the temperature range of 1773~1873 K using an improved sessile drop method with an alumina substrate in an Ar+3%H2 atmosphere. The error of the data obtained was analyzed. The surface tension of molten Ni and Ni-Co (5 and 10 mass fraction) alloys decreases with increasing temperature. The influence of Co on the surface tension of Ni-Co alloys is little in the studied Co concentration range.