Two design factors and one operation parameter of a methane fired crucible furnace are numerically explored in this work. These are the number of burners, the location of the exhaust gas exit, and the air-fuel ratio, ...Two design factors and one operation parameter of a methane fired crucible furnace are numerically explored in this work. These are the number of burners, the location of the exhaust gas exit, and the air-fuel ratio, respectively. Three dimensional steady state Computational Fluid Dynamics simulations are carried out in order to analyze the influence of the above factors on the mean cavity temperature in absence of thermal load, the methane content and the oxygen content of the exit gas.展开更多
文摘Two design factors and one operation parameter of a methane fired crucible furnace are numerically explored in this work. These are the number of burners, the location of the exhaust gas exit, and the air-fuel ratio, respectively. Three dimensional steady state Computational Fluid Dynamics simulations are carried out in order to analyze the influence of the above factors on the mean cavity temperature in absence of thermal load, the methane content and the oxygen content of the exit gas.