<正>According to the piezoelectric equation and the vibration theory of the quartz crystal,the relations between the vibrating frequency and structural parameters under the thickness-shear-vibration of AT-cut qu...<正>According to the piezoelectric equation and the vibration theory of the quartz crystal,the relations between the vibrating frequency and structural parameters under the thickness-shear-vibration of AT-cut quartz crystal have been studied. The frequency conditions under which quartz crystal resonator formed stationary wave inside the electrode district and the transmission characteristics of wave outside the electrode district have also been discussed.A quartz crystal resonator was developed based on this analysis.The experiment showed that the force-sensing characteristics were independent of the fixation of the crystal edge.The detecting distinguish ability was up to 0.001°,and the short-term frequency stability was up to 1.38×10~ (-10)/min.展开更多
Based on the analysis of one-dimension inertial accelerometer movement model,from which the resolution of the accelerometer inertial mass displacement equation was derived,the response of the sensor sensing element to...Based on the analysis of one-dimension inertial accelerometer movement model,from which the resolution of the accelerometer inertial mass displacement equation was derived,the response of the sensor sensing element to vibration and impact of various frequencies was studied.The theoretical and experimental results show that a reasonable configuration among the sensing element inherent frequency,environmental exciting frequency and the damp factors of the sensor is the key to prevent the sensor from damage.The sensor has good anti-vibrating impact ability when the relative damp factor is 0.7,and the environmental interferential vibrating frequency is less than 0.35 times of the inherent frequency of the sensing element.展开更多
The films of Ge and Si were grown on the substrate Si (100) by magnetron sputtering at 2.5 Pa Ar pressure.The growth temperature of films was 100℃,250℃,400℃and 550℃.The structure and composition were analysised by...The films of Ge and Si were grown on the substrate Si (100) by magnetron sputtering at 2.5 Pa Ar pressure.The growth temperature of films was 100℃,250℃,400℃and 550℃.The structure and composition were analysised by Raman scattering.The poly-crystal peak and crystal peak of Ge were observed in these films.The results indicate that the single crystal film of Ge was prepared at the substrate temperature of 400℃.The peak of acoustic phonons of Ge was 98 cm^(-1) and that of Si was 170 cm^(-1).展开更多
Intelligent drug delivery system based on “stimulus-response”mode emerging a promising perspective in next generation lipidbased nanoparticle.Here,we classify signal sources into physical and physiological stimulati...Intelligent drug delivery system based on “stimulus-response”mode emerging a promising perspective in next generation lipidbased nanoparticle.Here,we classify signal sources into physical and physiological stimulation according to their origin.展开更多
文摘<正>According to the piezoelectric equation and the vibration theory of the quartz crystal,the relations between the vibrating frequency and structural parameters under the thickness-shear-vibration of AT-cut quartz crystal have been studied. The frequency conditions under which quartz crystal resonator formed stationary wave inside the electrode district and the transmission characteristics of wave outside the electrode district have also been discussed.A quartz crystal resonator was developed based on this analysis.The experiment showed that the force-sensing characteristics were independent of the fixation of the crystal edge.The detecting distinguish ability was up to 0.001°,and the short-term frequency stability was up to 1.38×10~ (-10)/min.
文摘Based on the analysis of one-dimension inertial accelerometer movement model,from which the resolution of the accelerometer inertial mass displacement equation was derived,the response of the sensor sensing element to vibration and impact of various frequencies was studied.The theoretical and experimental results show that a reasonable configuration among the sensing element inherent frequency,environmental exciting frequency and the damp factors of the sensor is the key to prevent the sensor from damage.The sensor has good anti-vibrating impact ability when the relative damp factor is 0.7,and the environmental interferential vibrating frequency is less than 0.35 times of the inherent frequency of the sensing element.
基金supported by the National Natural Science Foundation of China(No.60272001)the Beijing Natural Science Foundation of China(No.4032010)the Yunnan Natural Province Science Foundation of China(Youth Foundation:No.K1010265)
文摘The films of Ge and Si were grown on the substrate Si (100) by magnetron sputtering at 2.5 Pa Ar pressure.The growth temperature of films was 100℃,250℃,400℃and 550℃.The structure and composition were analysised by Raman scattering.The poly-crystal peak and crystal peak of Ge were observed in these films.The results indicate that the single crystal film of Ge was prepared at the substrate temperature of 400℃.The peak of acoustic phonons of Ge was 98 cm^(-1) and that of Si was 170 cm^(-1).
基金This work was supported by Beijing Natural Science Foundation(7214283)the National Key Research&Development Program of China(grant Nos.2021YFA1201000 and 2018YFE0117800)+3 种基金National Natural Science Foundation of China(NSFC)Key Project(grant No.32030060)NSFC International CollaborationKey Project(grant No.51861135103)The authors also appreciate the support by the Beijing-Tianjin-Hebei Basic Research Cooperation Project(19JCZDJC64100)This study was also supported by the Science and Technology Development Fund,Macao SAR(File no.0124/2019/A3).
文摘Intelligent drug delivery system based on “stimulus-response”mode emerging a promising perspective in next generation lipidbased nanoparticle.Here,we classify signal sources into physical and physiological stimulation according to their origin.