期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Air-Water Cooling System for Switch-Mode Power Supplies
1
作者 g. casano S. Piva 《Journal of Electronics Cooling and Thermal Control》 2015年第3期66-75,共10页
The results are presented of an experimental investigation of heat transfer in an air-liquid cooling system for a Switch-Mode Power Supply (SMPS) for TV digital power amplifiers. Since these SMPSs are characterized by... The results are presented of an experimental investigation of heat transfer in an air-liquid cooling system for a Switch-Mode Power Supply (SMPS) for TV digital power amplifiers. Since these SMPSs are characterized by high power and high compactness, thereby making the standard cooling techniques difficult to be used, a new cooling system is developed, using water and air as the cooling media. The active components (MOSFETs) are cooled with a liquid cold-plate, the passive ones (condensers, transformers, coils) with an air flow, in turn cooled by the cold-plate. By inserting the cooling system in an experimental tool where it is possible to control the cooling water, measurements are made of temperature in the significant points of the SMPS. The electric efficiency is also measured. The evaluation of the thermal performance of this cooling system is useful in order to limit its maximum operational temperature. The efficacy of the cooling system is demonstrated;the trends of efficiency and power dissipation are evidenced. 展开更多
关键词 SWITCH MODE Power Supply SMPS Cold-Plate COOLING System THERMAL Design
下载PDF
Experimental Investigation of the Fluid Dynamics of a Finned Heat Sink under Operating Conditions
2
作者 g. casano M. W. Collins S. Piva 《Journal of Electronics Cooling and Thermal Control》 2014年第3期86-95,共10页
An experimental study has been made of the fluid dynamics performance of electronic equipment designed to cool a heat sink in the form of a finned duct. The apparatus consists of a channel of rectangular section conta... An experimental study has been made of the fluid dynamics performance of electronic equipment designed to cool a heat sink in the form of a finned duct. The apparatus consists of a channel of rectangular section containing the finned duct. A forced airflow is driven by three fans placed in parallel in the inlet and in the outlet sections of the channel. In order to investigate a full range of flow rates, different sets of fans were used in the inlet section. Measurements were made of static pressures at different channel positions by pressure taps connected to a micro manometer, and of the flow rate by a Venturi meter. The experimental working conditions of the active fans were consistent with the manufacturers’ characteristic curves. Values of the local friction coefficient compared well with published correlations. The experimental working points agreed very well with the theoretical curve of the pressure drop and the hydraulic diameter was demonstrated to be of the appropriate size for this fluid dynamics problem. 展开更多
关键词 AIRFLOW DUCT FLOW PRESSURE DROP
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部