The porous anodic alumina membranes (PAAMs) have been successfully used as templates for the fabrication of functional nano-materials due to their outstanding regularity and physicochemical properties. In this paper...The porous anodic alumina membranes (PAAMs) have been successfully used as templates for the fabrication of functional nano-materials due to their outstanding regularity and physicochemical properties. In this paper, a transparent double-sided anodic alumina membrane with ultra-thin aluminum substrate was fabricated with the three-step anodic oxidation method in the oxalic acid electrolyte. The characters such as the top-surface morphology, membrane thickness, and depth of nanopores of this three-layer (A1203-A1-A1203) sandwiched nano-structure were controllable through regulating the main anodic oxidation conditions, e.g., anodic oxidation time of various steps, coating remove process. The experiments data revealed that the aluminum substrate is exponential declined with the oxidation time when it was approximately reduced by a few micrometers. This new double-sided anodic alumina membrane can be used as the high-quality functional field emission materials and templates.展开更多
In the research of bio-molecular chips and sensors, extra electric biases are most often employed to control and manipulate the DNA and protein molecules moving through micro/nano-fluidic channels. In order to accurat...In the research of bio-molecular chips and sensors, extra electric biases are most often employed to control and manipulate the DNA and protein molecules moving through micro/nano-fluidic channels. In order to accurately and flexibly control the bio-molecules as they move within the channels, a clear understanding of how the current changes within the buffer solution caused by an applied bias is fundamental. In this report, the current changed value of different buffer solutions, e.g., KC1, TE, and TBE was systematically studied with real-time monitoring and quantitative analysis in the situation of the buffers moving through a fluidic channel with a 5 μm inner diameter, driven by biases of 50 or 100 mV. The results revealed that the relation- ship between the current changed value and the pause interval of the applied electric field is highly consistent with the Hill Equation, which is helpful for accurately detecting and manipulating single biomolecules in microfluidic sensors and biochips.展开更多
基金supported by the Major Research Plan of the National Nat-ural Science Foundation of China(Grant No.91123030)the International Cooperation Foundation of the National Science and Technology Major Project of the Ministry of Science and Technology of China(Grant No.2011DFA12220)the National Natural Science Foundation of China(Grant No.61378083)
文摘The porous anodic alumina membranes (PAAMs) have been successfully used as templates for the fabrication of functional nano-materials due to their outstanding regularity and physicochemical properties. In this paper, a transparent double-sided anodic alumina membrane with ultra-thin aluminum substrate was fabricated with the three-step anodic oxidation method in the oxalic acid electrolyte. The characters such as the top-surface morphology, membrane thickness, and depth of nanopores of this three-layer (A1203-A1-A1203) sandwiched nano-structure were controllable through regulating the main anodic oxidation conditions, e.g., anodic oxidation time of various steps, coating remove process. The experiments data revealed that the aluminum substrate is exponential declined with the oxidation time when it was approximately reduced by a few micrometers. This new double-sided anodic alumina membrane can be used as the high-quality functional field emission materials and templates.
基金supported by the Major Research Plan of the National Natural Science Foundation of China(Grant No.91123030)the Interna-tional Cooperation Foundation of the National Science and Technology Major Project of the Ministry of Science and Technology of China(Grant No.2011DFA12220)the National Natural Science Foundation of China(Grant No.61378083)
文摘In the research of bio-molecular chips and sensors, extra electric biases are most often employed to control and manipulate the DNA and protein molecules moving through micro/nano-fluidic channels. In order to accurately and flexibly control the bio-molecules as they move within the channels, a clear understanding of how the current changes within the buffer solution caused by an applied bias is fundamental. In this report, the current changed value of different buffer solutions, e.g., KC1, TE, and TBE was systematically studied with real-time monitoring and quantitative analysis in the situation of the buffers moving through a fluidic channel with a 5 μm inner diameter, driven by biases of 50 or 100 mV. The results revealed that the relation- ship between the current changed value and the pause interval of the applied electric field is highly consistent with the Hill Equation, which is helpful for accurately detecting and manipulating single biomolecules in microfluidic sensors and biochips.