期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
A DUAL-MODALITY OPTICAL BIOPSY APPROACH FOR IN VIVO DETECTION OF PROSTATE CANCER IN RAT MODEL
1
作者 VIKRANT SHARMA NIMIT PATEL +3 位作者 JINHUI SHEN LIPING TANG george alexandrakis HANLI LIU 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2011年第3期269-277,共9页
Ultrasound-guided biopsy procedure for prostate cancer diagnosis,which is the current gold standard,involves quasi-random sampling of prostate tissue without any functional guidance.In this study,we discuss the possib... Ultrasound-guided biopsy procedure for prostate cancer diagnosis,which is the current gold standard,involves quasi-random sampling of prostate tissue without any functional guidance.In this study,we discuss the possibility to augment the detection of prostate cancer using a dual-modality optical approach,which can be coupled with the current needle biopsy setup.Two techniques are light reflectance spectroscopy(LRS)that uses a broadband light source and a CCD array spectrometer,and auto-fluorescence lifetime measurement(AFLM)that uses a custom-designed,time-correlated single photon counting(TCSPC)system.Both LRS and AFLM were employed sequentially in this study to measure cancer tissue along with control tissue on a rat prostate tumor model.At an excitation wavelength of 447 nm,we investigated auto-fluorescence decay curves at the emission wavelengths of 532,562,632 and 684 nm for in vivo and ex vivo AFLM.These results show that auto-fluorescence lifetimes at all measured emission wavelengths differ between control and cancerous tissues with 100% specificity and sensitivity.Moreover,absolute values of hemoglobin derivatives and scattering coe±cient were quantified using in vivo LRS.This part of study also demonstrates that light scattering and absorption are significantly different between the control and cancerous tissue.Overall,the study demonstrates that both LRS and AFLM may provide several intrinsic biomarkers for in vivo detection of prostate cancer. 展开更多
关键词 Prostate cancer light reflectance spectroscopy auto-fluorescence lifetime
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部