This paper built a combined heat and power(CHP) dispatch model for wind-CHP system with solid heat storage device(SHS) aiming at minimizing system coal consumption, and set system demand-supply balance and units'...This paper built a combined heat and power(CHP) dispatch model for wind-CHP system with solid heat storage device(SHS) aiming at minimizing system coal consumption, and set system demand-supply balance and units' operation conditions as the operation constraints. Furthermore, robust stochastic optimization theory was used to describe wind power output uncertainty. The simulation result showed that SHS increased CHP peak-valley shifting capability and reduced abandoned wind rate from 12% to 6%, and reduced 5% coal consumption, compared with the original system operation by flexible charging electric power and heating. The payback period of employing SHS in wind-CHP system is far shorter than SHS expected service life.展开更多
基金Supported by the Fundamental Research Funds for the National Science Foundation of China(71573084)
文摘This paper built a combined heat and power(CHP) dispatch model for wind-CHP system with solid heat storage device(SHS) aiming at minimizing system coal consumption, and set system demand-supply balance and units' operation conditions as the operation constraints. Furthermore, robust stochastic optimization theory was used to describe wind power output uncertainty. The simulation result showed that SHS increased CHP peak-valley shifting capability and reduced abandoned wind rate from 12% to 6%, and reduced 5% coal consumption, compared with the original system operation by flexible charging electric power and heating. The payback period of employing SHS in wind-CHP system is far shorter than SHS expected service life.