Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas 被引量:7
1
作者 gabor nemeth Eszter Szalai +3 位作者 Ziad Hassan Agnes Lipecz Zsuzsa Flasko Laszlo Modis 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第2期217-222,共6页
AIM: To analyze the correlations between ocular biomechanical and biometric data of the eye,measured by Scheimpflug-based devices on healthy subjects.METHODS: Three consecutive measurements were carried out using th... AIM: To analyze the correlations between ocular biomechanical and biometric data of the eye,measured by Scheimpflug-based devices on healthy subjects.METHODS: Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology(Cor Vis ST) device on healthy eyes and the 10 device-specific parameters were recorded.Pentacam HR-derived parameters(corneal curvature radii on the anterior and posterior surfaces;apical pachymetry;corneal volume;corneal aberration data;depth,volume and angle of the anterior chamber) and axial length(AL) from IOLMaster were correlated with the 10 specific CorV is ST parameters.RESULTS: Measurements were conducted in 43 eyes of 43 volunteers(age 61.24±15.72y).The 10 specific Cor Vis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface,pachymetric data,root mean square(RMS) data of lower-order aberrations,and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea.Anterior chamber depth showed a significant relationship,but there were no significant correlations between corneal volume,anterior chamber volume,mean chamber angle or AL and the 10 specific CorV is ST parameters.CONCLUSION: Cor Vis ST-generated parameters are influenced by corneal curvature radii,some corneal RMS data,but corneal volume,anterior chamber volume,chamber angle and AL have no correlation with the biomechan-ical parameters.The parameters measured by CorV is ST seem to refer mostly to corneal properties of the eye. 展开更多
关键词 anterior segment parameters biomechan-ics corneal visualization Scheimpflug technology OcularResponse Analyzer
下载PDF
Scheimpflug imaged corneal changes on anterior and posterior surfaces after collagen cross-linking 被引量:1
2
作者 Ziad Hassan Laszlo Modis +2 位作者 Eszter Szalai Andras Berta gabor nemeth 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期313-316,共4页
AIM:To compare the anterior and posterior corneal parameters before and after collagen cross-linking therapy for keratoconus.METHODS:Collagen cross-linking was performed in31 eyes of 31 keratoconus patients(mean age 3... AIM:To compare the anterior and posterior corneal parameters before and after collagen cross-linking therapy for keratoconus.METHODS:Collagen cross-linking was performed in31 eyes of 31 keratoconus patients(mean age 30.6±8.9y).Prior to treatment and an average 7mo after therapy,Scheimpflug analysis was performed using Pentacam HR.In addition to corneal thickness assessments,corneal radius,elevation,and aberrometric measurements were performed both on anterior and posterior corneal surfaces.Data obtained before and after surgery were statistically analyzed.RESULTS:In terms of horizontal and vertical corneal radius,and central corneal thickness no deviations were observed an average 7mo after operation.Corneal higher order aberration showed no difference neither on anterior nor on posterior corneal surfaces.During follow-up period,no significant deviation was detected regarding elevation values obtained by measurement in mm units between the 3.0-8.0 mm-zones.CONCLUSION:Corneal stabilization could be observed in terms of anterior and posterior corneal surfaces,elevation and higher order aberration values 7mo after collagen cross-linking therapy for keratoconus. 展开更多
关键词 corneal back surface higher order aberration elevation collagen cross-linking high resolution Pentacam
下载PDF
Ocular biomechanical measurements on post- keratoplasty corneas using a Scheimpflug-based noncontact device 被引量:1
3
作者 Laszlo Modis Jr. Ziad Hassan +3 位作者 Eszter Szalai Zsuzsanna Flasko Andras Berta gabor nemeth 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第2期235-238,共4页
AIM: To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (lOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. ... AIM: To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (lOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas. METHODS: Measurements were conducted on 46 eyes of 46 healthy patients without any corneal pathology (age: 53.83 ±20.8y) and 30 eyes of 28 patients after penetrating keratoplasty (age: 49.43 ±21.34y). Ten biomechanical parameters, the CCT and lOP were recorded by corneal visualization Scheimpflug technology (CorVis ST) using high-speed Scheimpflug imaging. Keratometry values were also recorded using Pentacam HR system. Scheimpflug measurements were performed after 43.41± 40.17mo (range: 11-128mo) after the keratoplasty and after 7.64±2.34mo (range: 5-14mo) of suture removal. RESULTS: Regarding the device-specific biomechanical parameters, the highest concavity time and radius values showed a significant decrease between these two groups (P=0.01 and P 〈0.001). None of other biomechanical parameters disclosed a significant difference. The CCT showed a significant difference between post keratoplasty eyes as compared to normal subjects (P= 0.003) using the CorVis ST device. The lOP was within the normal range in both groups (P=0.84). There were no significant relationships between the keratometric data, the size of the donor and recipient, age of the donor and recipient and biomechanical properties obtained by CorVis ST. CONCLUSION: The ocular biomechanics remain stable after penetrating keratoplasty according to the CorVis ST measurements. Only two from the ten device-specific parameters have importance in the follow-up period after penetrating keratoplasty. 展开更多
关键词 corneal visualization Scheimpflugtechnology ocular biomechanics penetrating keratoplasty
下载PDF
Anterior segment parameters associated with extramuscular manifestations in polymyositis and dermatomyositis
4
作者 Zoltan Griger Katalin Danko +8 位作者 gabor nemeth Ziad Hassan Zsuzsa Aszalos Katalin Szabo Levente Bodoki Rudolf Gesztelyi Judit Zsuga Peter Szodoray Adam Kemeny-Beke 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第9期1443-1450,共8页
AIM:To evaluate detailed anterior segment parameters of patients with idiopathic inflammatory myopathies(IIM),including polymyositis(PM),and dermatomyositis(DM),and to clarify the associations between these data and c... AIM:To evaluate detailed anterior segment parameters of patients with idiopathic inflammatory myopathies(IIM),including polymyositis(PM),and dermatomyositis(DM),and to clarify the associations between these data and clinical variables of IIM.METHODS:Totally 57 PM,41 DM patients and 62 controls were enrolled in this cross-sectional,observational,case-control study.All study participants underwent Pentacam evaluation.Laboratory investigations consisted of different antibody assays,while extramuscular clinical assessments included Raynaud’s phenomenon,dysphagia,interstitial lung disease,arthritis/arthralgia,and weight loss.Objective signs and subjective symptoms of dry eye disease(DED)were also evaluated.RESULTS:All pachymetric parameters[center,apex,thinnest and maximal keratometry(Kmax)]and corneal volume(CV)of both sides of PM patients proved to be significantly lower.Some pachymetric data were also noticed as significantly decreased compared to those of controls.Several significant differences were traced between anterior segment values and extramuscular manifestations of myositis,largely in case of arthritis/arthralgia and weight loss,whereas associations between anterior segment parameters and antibodies were weak.Objective clinical tests of DED were also significantly decreased in IIM patients.CONCLUSION:The results suggest that all IIM patients have thinner corneas compared with those of controls,and decreased corneal parameters are significantly associated with the occurrence of some extramuscular manifestations.In addition,IIM patients tend to develop objective signs of DED. 展开更多
关键词 dry eye extramuscular manifestations DERMATOMYOSITIS POLYMYOSITIS Scheimpflug imaging