期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Fluid Vibration Induced in T-Junction with Double Side Branches 被引量:1
1
作者 Ryuhei Yamaguchi gaku tanaka +1 位作者 Hao Liu Toshiyuki Hayase 《World Journal of Mechanics》 2016年第4期169-179,共11页
A T-junction is a fundamental fluid element prevalent in pipe networks of water supplies and power plants. In the present study, a double T-junction was investigated for flow instability and fluid vibration. Both axi-... A T-junction is a fundamental fluid element prevalent in pipe networks of water supplies and power plants. In the present study, a double T-junction was investigated for flow instability and fluid vibration. Both axi-aligned and skewed double T-junctions are examined from viewpoint of flow instability. With single-phase flow in an open-ended double T-junction, fluid vibration is induced in both side branches because of a high shear rate with a point of inflection. The frequency of vibration in the downstream branch is higher than that in the upstream branch. Except for the upstream branch in the skewed double T-junction, the frequency is higher than that in a single T-junction. The fluid vibrations are closely associated with the fluid interference created by the presence of the two side branches. 展开更多
关键词 Fluid Vibration Flow Instability Shear Rate Double T-Junction Particle Image Velocimetry Laser Doppler Anemometry
下载PDF
Numerical Simulation of Flow Behavior in Basilar Bifurcation Aneurysms Based on 4-Dimensional Computed Tomography Angiography
2
作者 Tomoaki Yamazaki gaku tanaka +4 位作者 Ryuhei Yamaguchi Yodai Okazaki Hitomi Anzai Fujimaro Ishida Makoto Ohta 《World Journal of Mechanics》 2021年第4期71-82,共12页
Initiation, growth, and rupture of cerebral aneurysms are caused by hemodynamic factors. It is extensively accepted that the cerebral aneurysm wall is assumed to be rigid using computational fluid dynamics (CFD). Furt... Initiation, growth, and rupture of cerebral aneurysms are caused by hemodynamic factors. It is extensively accepted that the cerebral aneurysm wall is assumed to be rigid using computational fluid dynamics (CFD). Furthermore, fluid-structure interactions have been recently applied for simulation of an elastic cerebral aneurysm model. Herein, we examined cerebral aneurysm hemodynamics in a realistic moving boundary deformation model based on 4-dimensional computed tomographic angiography (4D-CTA) obtained by high time-resolution using numerical simulation. The aneurysm of the realistic moving deformation model based on 4D-CTA at each phase was constructed. The effect of small wall deformation on hemodynamic characteristics might be interested. So, four hemodynamic factors (wall shear stress, wall shear stress divergence, oscillatory shear index and residual residence time) were determined from the numerical simulation, and their behaviors were assessed in the basilar bifurcation aneurysm. 展开更多
关键词 Basilar Bifurcation Aneurysm 4-Dimensional Computed Tomographic Angiography Moving Boundary Method
下载PDF
Effects of Elasticity on Wall Shear Stress in Patient-Specific Aneurysm of Cerebral Artery 被引量:1
3
作者 Ryuhei Yamaguchi Taihei Kotani +8 位作者 gaku tanaka Simon Tupin Kahar Osman Nadia Shaira Shafii Ahmad Zahran Md Khudzari Kazuhiro Watanabe Hitomi Anzai Atsushi Saito Makoto Ohta 《Journal of Flow Control, Measurement & Visualization》 2019年第2期73-86,共14页
The behavior of wall shear stress (WSS) was previously reported in a deformable aneurysm model using fluid-structure interactions. However, these findings have not been validated. In the present study, we examined the... The behavior of wall shear stress (WSS) was previously reported in a deformable aneurysm model using fluid-structure interactions. However, these findings have not been validated. In the present study, we examined the effect of elasticity (i.e., deformation) on wall shear stress inside a cerebral aneurysm at the apex of a bifurcation using particle image velocimetry in vitro. The flow model simulated a human patient-specific aneurysm at the apex of the bifurcation of the middle cerebral artery. Flow characteristics by wall elasticity were examined for both elastic and non-deformable aneurysm models with pulsatile blood flow. The absolute temporally- and spatially-averaged WSS along the bleb wall was smaller in the elastic model than that in the non-deformable model. This small WSS may be related to attenuation of the WSS. Further, the WSS gradient had a finite value near the stagnation point of the aneurysm dome. Finally, the WSS gradient near the stagnation point was slightly smaller in the elastic model than that in the non-deformable model. These data suggest that elasticity of the aneurysm wall can affect the progression and rupture of aneurysms via hemodynamic stress. 展开更多
关键词 CEREBRAL ANEURYSM ELASTICITY Particle Image VELOCIMETRY Wall SHEAR Stress
下载PDF
Universality of Periodic Oscillation Induced in Side Branch of a T-Junction in Numerical Simulation 被引量:1
4
作者 Ryuhei Yamaguchi gaku tanaka +3 位作者 Tadashi Nakagawa Atsushi Shirai Hao Liu Toshiyuki Hayase 《Journal of Flow Control, Measurement & Visualization》 2017年第4期73-85,共13页
The flow instability through the side branch of a T-junction is analyzed in a numerical simulation. In a previous experimental study, the authors clarified the mechanism of fluid-induced vibration in the side branch o... The flow instability through the side branch of a T-junction is analyzed in a numerical simulation. In a previous experimental study, the authors clarified the mechanism of fluid-induced vibration in the side branch of the T-junction in laminar steady flow through the trunk. However, in that approach there were restrictions with respect to extracting details of flow behavior such as the flow instability and the distribution of wall shear stress along the wall. Here the spatial growth of the velocity perturbation at the upstream boundary of the side branch is investigated. The simulation result indicates that a periodic velocity fluctuation introduced at the upstream boundary is amplified downstream, in good agreement with experimental result. The fluctuation in wall shear stress because of the flow instability shows local extrema in both the near and distal walls. From the numerical simulation, the downstream fluid oscillation under a typical condition has a Strouhal number of 1.05, which approximately agrees with the value obtained in experiments. Therefore, this periodic oscillation motion is a universal phenomenon in the side branch of a T-junction. 展开更多
关键词 Flow INSTABILITY Fluid-Induced OSCILLATION NUMERICAL Simulation SIMPLER Method T-JUNCTION
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部