The Gradient of γ-Rays Irradiation’s Energy and Its Use in Treatment of Cancer Diseases
1
作者 Labinot Kastrati gazmend nafezi +1 位作者 zim Shehi 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2016年第2期150-153,共4页
The Ionising irradiations used mostly in the treatment of tumoral diseasses are: X, γ, β and e irradiations. The discussion will be about γ irradiations, produced in linear accelerator with photon energy 6 MV and 1... The Ionising irradiations used mostly in the treatment of tumoral diseasses are: X, γ, β and e irradiations. The discussion will be about γ irradiations, produced in linear accelerator with photon energy 6 MV and 15 MV. It is important to know the absorption performance before and after the electronic equilibrium. This is a reason that we’ve used the function of dose gradient for irradiations γ. It represents the velocity of dose change as a function of depth in tissue. From skin to maximum dose value, the increase of G-function is more accentuated for γ-rays than for β-particles while after that the G-function decreasing is less sharp for γ-rays. Finally, we’ll discuss about the advantages in terms of radiation protection of γ-rays used in radiotherapy. 展开更多
关键词 γ-Rays G-FUNCTION Photon Energy Radiation Protection
下载PDF
Dose Distribution of Photon Beam by Siemens Linear Accelerator
2
作者 Besim Xhafa Tatjana Mulaj +1 位作者 Gezim Hodolli gazmend nafezi 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2014年第1期67-70,共4页
The radiation therapy is applied on around 50% of the cancer patients. As we know, before implementing a radiation treatment planning system in the clinic, the dose-calculation measurement must be validated using rigo... The radiation therapy is applied on around 50% of the cancer patients. As we know, before implementing a radiation treatment planning system in the clinic, the dose-calculation measurement must be validated using rigorous, clinically relevant criteria [1]. Percent Depth Doses (PDD), Dose Profile (DP), Open Collimator Factor (OCF) etc., are measured for all numbers of square fields for Treatment Planning System XiO, version 4.7, for 6 and 15 MV photons energies and for 15°, 30°, 45°, 60° wedge, which were employed to obtain the profiles in any depth. The measurements were conducted also for different energies of electron beam and TPS calculation algorithms. 展开更多
关键词 RADIATION Absorbed DOSE Measurements PERCENT DOSE DEPTH DOSE PROFILE Treatment Planning System