期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Experimental Evaluating of the Physical, Mechanical and Durability Properties of Natural, Recycled and Both Combined Aggregates Based Concretes
1
作者 Etienne Malbila Arba A.T. Ouedraogo +3 位作者 Nicolas Kagambega gilbert g. nana Sié Kam David Y. K. Toguyeni 《Materials Sciences and Applications》 2023年第3期117-141,共25页
This experimental study aims at the reuse of recycled aggregates (RA), resulting from the demolition of concrete, cement block and cement mortar, in the manufacture of common construction in Burkina Faso. The RA can r... This experimental study aims at the reuse of recycled aggregates (RA), resulting from the demolition of concrete, cement block and cement mortar, in the manufacture of common construction in Burkina Faso. The RA can readily replace natural aggregates in concrete. Then five formulations of natural and recycled aggregates based concrete for characteristic strength of 25 Mpa were prepared in addition to the natural aggregates base concrete named reference concrete (BN): two types of recycled aggregates concrete (BR), three types of recycles and natural combined aggregates base concrete (BC). The properties of natural and recycled aggregates were characterized and the physical, mechanical strength and durability properties were also evaluated for all concrete specimens. All the studied concrete formulation present a density between 2000 kg/m<sup>3</sup> ≤ ρ ≥ 2600 kg/m<sup>3</sup> and an average slump of 4.9 ± 0.1 cm. The obtained results indicate that the recycled aggregates are suitable for current concrete. Two out of the five combinations studied, such as the natural (BN) and combined aggregate (BC2) based concretes satisfy the mechanical characteristics (Rc<sub>28</sub> > 25 MPa) at 28 days of age and an average absorption coefficient of 2.93% and 3.98%. The recycled aggregate based concrete (BR1, BR2) and combined aggregate based concrete (BC1), gave respective average compressive strength of 21.55 MPa, 20.50 MPa and 20.30 MPa, i.e. a difference of 13.80% to 18.80% under the characteristic strength (25 MPa) aimed at 28 days of age. Thus, the recycled aggregates are in conformity with the normative prescriptions and their use for standard concrete gives adequate physical, mechanical and durability properties for the production of the C20/25 concrete series in the common civil engineering applications. 展开更多
关键词 Concrete Demolition Waste Aggregate Recycled Aggregate Strength Water Absorption
下载PDF
Establishment of a Model for the Calculation of the COP of a Solar Adsorption Refrigerator
2
作者 Amadou Konfe gilbert g. nana +1 位作者 Salif Ouedraogo Sié Kam 《Smart Grid and Renewable Energy》 2023年第11期197-208,共12页
This paper deals with the evaluation of the Coefficient of Performance (COP) of solar adsorption refrigeration. In the literature, simulation models to predict the thermal behaviour and the coefficient of performance ... This paper deals with the evaluation of the Coefficient of Performance (COP) of solar adsorption refrigeration. In the literature, simulation models to predict the thermal behaviour and the coefficient of performance of these systems are uncommon. This is why we suggest a model to simulate the operation of the machine in a typical hot and dry climate of the city of Ouagadougou. The objective is to provide a model for calculating the COP from the measurement of the ambient temperature and the irradiation of a given site. Starting from mathematical modelling, a resolution and simulation were made with COMSOL software based on the Dubinin-Astakhov adsorption model, the heat transfer balance equations, and the Linear Driving Force (LDF) model to describe the thermal behaviour of the system. A one-week measurement sequence on the adsorption solar refrigerator at the Albert Schweitzer Ecological Centre (CEAS) validated the numerical results. The measurement shows that for the days with high sunshine, the temperature of the reaction medium reaches 110°C, and the pressure reaches 500 mbar. This leads to a production of cold that allows it to reach the temperature of -5°C at the evaporator. Under these conditions, the COP is worth 14%. These results are obtained both by numerical simulation using the COMSOL 5.1 software and after a measurement session on the solar refrigerator available to the CEAS. We obtained an experimental and theoretical coefficient of performance varying between 9% and 14% with a difference of between 0% and 3%. We conclude that our model is suitable to estimate the COP of any device based on its thermal properties, the ambient temperature and the irradiation of a given site. 展开更多
关键词 SOLAR REFRIGERATION ADSORPTION Coefficient of Performance Modelling
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部