期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Comparison of novel and standard diagnostic tools for the detection of Schistosoma mekongi infection in Lao People’s Democratic Republic and Cambodia 被引量:4
1
作者 Youthanavanh Vonghachack Somphou Sayasone +9 位作者 Virak Khieu Robert Bergquist govert jvan dam Pytsje THoekstra Paul L.A.M.Corstjens Beatrice Nickel Hanspeter Marti Jürg Utzinger Sinuon Muth Peter Odermatt 《Infectious Diseases of Poverty》 SCIE 2017年第1期1123-1135,共13页
Background:Given the restricted distribution of Schistosoma mekongi in one province in Lao People’s Democratic Republic(Lao PDR)and two provinces in Cambodia,together with progress of the national control programmes ... Background:Given the restricted distribution of Schistosoma mekongi in one province in Lao People’s Democratic Republic(Lao PDR)and two provinces in Cambodia,together with progress of the national control programmes aimed at reducing morbidity and infection prevalence,the elimination of schistosomiasis mekongi seems feasible.However,sensitive diagnostic tools will be required to determine whether elimination has been achieved.We compared several standard and novel diagnostic tools in S.mekongi-endemic areas.Methods:The prevalence and infection intensity of S.mekongi were evaluated in 377 study participants from four villages in the endemic areas in Lao PDR and Cambodia using Kato-Katz stool examination,antibody detection based on an enzyme-linked immunosorbent assay(ELISA)and schistosome circulating antigen detection by lateral-flow tests.Two highly sensitive test systems for the detection of cathodic and anodic circulating antigens(CCA,CAA)in urine and serum were utilized.Results:Stool microscopy revealed an overall prevalence of S.mekongi of 6.4%(one case in Cambodia and 23 cases in Lao PDR),while that of Opisthorchis viverrini,hookworm,Trichuris trichiura,Ascaris lumbricoides and Taenia spp.were 50.4%,28.1%,3.5%,0.3%and 1.9%,respectively.In the urine samples,the tests for CCA and CAA detected S.mekongi infections in 21.0%and 38.7%of the study participants,respectively.In the serum samples,the CAA assay revealed a prevalence of 32.4%,while a combination of the CAA assay in serum and in urine revealed a prevalence of 43.2%.There was a difference between the two study locations with a higher prevalence reached in the samples from Lao PDR.Conclusions:The CCA,CAA and ELISA results showed substantially higher prevalence estimates for S.mekongi compared to Kato-Katz thick smears.Active schistosomiasis mekongi in Lao PDR and Cambodia might thus have been considerably underestimated previously.Hence,sustained control efforts are still needed to break transmission of S.mekongi.The pivotal role of highly sensitive diagnostic assays in areas targeting elimination cannot be overemphasised. 展开更多
关键词 Cambodia Food-borne trematodes Kato-Katz Lao People’s Democratic Republic Point-of-care circulating cathodic antigen Schistosoma mekongi SEROLOGY Soil-transmitted helminths Up-converting phosphorlateral-flow circulating anodic antigen
原文传递
Selecting accurate post-elimination monitoring tools to prevent reemergence of urogenital schistosomiasis in Morocco:a pilot study
2
作者 Abdelaali Balahbib Fatima Amarir +7 位作者 Paul L.A.M.Corstjens Claudia Jde Dood govert jvan dam Amina Hajli Meryem Belhaddad Bouchra El Mansouri Abderrahim Sadak Mohamed Rhajaouim El Bachir Adlaoui 《Infectious Diseases of Poverty》 SCIE 2017年第1期664-672,共9页
Background:After alleged stop of transmission of schistosomiasis and further down the line in post elimination settings,sensitive tools are required to monitor infection status to prevent potential re-emergence.In Rah... Background:After alleged stop of transmission of schistosomiasis and further down the line in post elimination settings,sensitive tools are required to monitor infection status to prevent potential re-emergence.In Rahala,where transmission cycle of Schistosoma haematobium is interrupted since 2004 but where 30%of snails are still infected by S.bovis,potential human S.bovis infection can’t be excluded.As methods based on egg-counts do not provide the required sensitivity,antibody or antigen assays are envisaged as the most appropriate tools for this type of monitoring.Methods:In this pilot study,the performances of three assays were compared:two commercially available antibody tests(ELISA and haemagglutination format)indicating exposure,and an antigen test(lateral flow strip format)demonstrating active infection.All 37 recruited study participants resided in Rahala(Akka,province Tata,Morocco).Participants had been diagnosed and cured from schistosomiasis in the period between 1983 and 2003.In 2015 these asymptomatic participants provided fresh clinical samples(blood and urine)for analysis with the aforementioned diagnostics tests.Results:No eggs were identified in the urine of the 37 participants.The haemagglutination test indicated 6 antibody positives whereas the ELISA indicated 28 antibody positives,one indecisive and one false positive.ELISA and haemagglutination results matched for 18 individuals,amongst which 5 out of 6 haemagglutination positives.With the antigen test(performed on paired serum and urine samples),serum from two participants(cured 21 and 32 years ago)indicated the presence of low levels of the highly specific Schistosoma circulating anodic antigen(CAA),demonstrating low worm level infections(less than 5 pg/ml corresponding to probably single worm pair).One tested also CAA positive with urine.ELISA indicated the presence of human anti-Schistosoma antibodies in these two CAA positive cases,haemagglutination results were negative.Conclusions:To prevent reemergence of schistosomiasis in Morocco current monitoring programs require specific protocols that include testing of antibody positives for active infection by the UCP-LF CAA test,the appropriate diagnostic tool to identify Schistosoma low grade infections in travelers,immigrants and assumed cured cases.The test is genus specific will also identify infections related to S.bovis. 展开更多
关键词 SCHISTOSOMIASIS Transmission stop ELIMINATION MONITORING Antibody test Antigen test Circulating Anodic Antigen(CAA) Active infection
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部