Effect of the Microclimate of Underground Systems on the Occurrence of Hibernating Bats
1
作者 grzegorz klys 《Journal of Environmental Science and Engineering(B)》 2013年第1期36-45,共10页
This study investigates the microclimatic connections between underground systems and the hibernation sites of particular species of bats. The distribution of hibernating bats was analysed in five selected zones desig... This study investigates the microclimatic connections between underground systems and the hibernation sites of particular species of bats. The distribution of hibernating bats was analysed in five selected zones designated Ⅰ-Ⅴ. These zones have a similar relative humidity, diverse temperature ranges inside the system, as well as air flow rates. A multi-year research programme highlighted the relationships between the occurrence of hibernating bats of various species and the microclimate of these particular zones. What is of essential importance are the sites with an air flow in their zones exceeding 0.02 m·s^-1, then is temperature and humidity. The air flow determines more intensive settling of wintering bats (zones Ⅲ, Ⅳand Ⅴ). The zone Ⅱ-tourist zone with periodic air flows and often visited by humans is the least used by hibernating bats. 展开更多
关键词 CHIROPTERA MICROCLIMATE AIRFLOW hibernating bats.