期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
High-precision and wide-range real-time neutron flux monitor system through multipoint linear calibration 被引量:4
1
作者 Ren-Jie Zhu Xiang Zhou +9 位作者 Zi-Hao Liu Wen-Di Wang Xiao-Li Mou Teng-Fei Fang Qing-Li Ma Xiu-Feng Xu guo-liang yuan Li Zhao Ling-Feng Wei Ze-Jie Yin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第9期98-106,共9页
The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test rea... The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test reactor,and HL-2 A.Neutron fluxes can provide real-time parameters for nuclear fusion,including neutron source intensity and fusion power.Corresponding to different nuclear reaction periods,neutron fluxes span over seven decades,thereby requiring electronic devices to operate in counting and Campbelling modes simultaneously.Therefore,it is crucial to design a real-time NFM system to encompass such a wide dynamic range.In this study,a high-precision NFM system with a wide measurement range of neutron flux is implemented using realtime multipoint linear calibration.It can automatically switch between counting and Campbelling modes with variations in the neutron flux.We established a testing platform to verify the feasibility of the NFM system,which can output the simulated neutron signal using an arbitrary waveform generator.Meanwhile,the accurate calibration interval of the Campbelling mode is defined well.Based on the above-mentioned design,the system satisfies the requirements,offering a dynamic range of 10~8 cps,temporal resolution of 1 ms,and maximal relative error of 4%measured at the signal-to-noise ratio of 15.8 dB.Additionally,the NFM system is verified in a field experiment involving HL-2 A,and the measured neutron flux is consistent with the results. 展开更多
关键词 Multipoint linear calibration Real time Simulated neutron signal Neutron flux monitoring ITER HL-2A
下载PDF
Characterization of 17-4PH stainless steel powders produced by supersonic gas atomization 被引量:2
2
作者 Xin-ming Zhao Jun Xu +3 位作者 Xue-xin Zhu Shao-ming Zhang Wen-dong Zhao guo-liang yuan 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2012年第1期83-88,共6页
17-4PH stainless steel powders were prepared using a supersonic nozzle in a close-coupled gas atomization system. The characteristics of powder particles were carried out by means of a laser particle size analyzer, sc... 17-4PH stainless steel powders were prepared using a supersonic nozzle in a close-coupled gas atomization system. The characteristics of powder particles were carried out by means of a laser particle size analyzer, scanning electron microscopy (SEM), and the X-ray diffraction (XRD) technique. The results show that the mass median particle diameter is about 19.15 prn. Three main types of surface microstructures are observed in the powders: well-developed dendrite, cellular, and cellular dendrite structure. The XRD measurements show that, as the particle size decreases, the amount of fcc phase gradually decreases and that of bcc phase increases. The cooling rate is inversely related to the particle size, i.e., it decreases with an increase in particle size. 展开更多
关键词 gas atomization metal powder stainless steel metal injection molding
下载PDF
A study of beryllium moderator thickness for a fission chamber with fast neutron measurements
3
作者 Wen-Di Wang Hong-Rui Cao +2 位作者 Jing Cao guo-liang yuan Ze-Jie Yin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第9期51-56,共6页
The detection efficiency of the fission chamber(FC) is very important for studying the neutron flux measurement(NFM) system in ITER. In this article, we mainly focus our attention on the influence of the moderator. Wi... The detection efficiency of the fission chamber(FC) is very important for studying the neutron flux measurement(NFM) system in ITER. In this article, we mainly focus our attention on the influence of the moderator. With the Monte Carlo particle transport simulation tool named Geant4, we make a simulation of FC detection efficiency with different levels of thickness of a beryllium moderator.Two manufactured FCs for ITER-NFM systems are then used to test the parameters and performance. The test results agree well with our simulation. 展开更多
关键词 中子测量 慢化剂 裂变室 厚度 GEANT4 测量系统 模拟工具
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部